Anodic stripping voltammetric determination of mercury using multi-walled carbon nanotubes film coated glassy carbon electrode

被引:0
|
作者
Hongchao Yi
机构
[1] Hubei Agriculture College,Department of Environmental Engineering
来源
Analytical and Bioanalytical Chemistry | 2003年 / 377卷
关键词
Multi-walled carbon nanotubes; Mercury; Determination; Chemically modified electrode; Anodic stripping voltammetry;
D O I
暂无
中图分类号
学科分类号
摘要
An electrochemical method for the determination of trace levels of mercury based on a multi-walled carbon nanotubes (MWNT) film coated glassy carbon electrode (GCE) is described. In 0.1 mol L−1 HCl solution containing 0.02 mol L−1 KI, Hg2+ was firstly preconcentrated at the MWNT film and then reduced at −0.60 V. During the anodic potential sweep, reduced mercury was oxidized, and then a sensitive and well-defined stripping peak at about −0.20 V appeared. Under identical conditions, a MWNT film coated GCE greatly enhances the stripping peak current of mercury in contrast to a bare GCE. Low concentrations of I− remarkably improve the determining sensitivity, since this increases the accumulation efficiency of Hg2+ at the MWNT film coated GCE. The stripping peak current is proportional to the concentration of Hg2+ over the range 8×10−10–5×10−7 mol L−1. The lowest detectable concentration of Hg2+ is 2×10−10 mol L−1 at 5 min accumulation. The relative standard deviation (RSD) at 1×10−8 mol L−1 Hg2+ was about 6% (n=10). By using this proposed method, Hg2+ in some water samples was determined, and the results were compared with those obtained by atomic absorption spectrometry (AAS). The two results are similar, suggesting that the MWNT-film coated GCE has great potential in practical analysis.
引用
收藏
页码:770 / 774
页数:4
相关论文
共 50 条
  • [1] Anodic stripping voltammetric determination of mercury using multi-walled carbon nanotubes film coated glassy carbon electrode
    Yi, HC
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (04) : 770 - 774
  • [2] Voltammetric determination of the herbicide propham on glassy carbon electrode modified with multi-walled carbon nanotubes
    Leniart, Andrzej
    Brycht, Mariola
    Burnat, Barbara
    Skrzypek, Slawomira
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 231 : 54 - 63
  • [3] Sensitive voltammetric determination of tyrosine using multi-walled carbon nanotubes/4-aminobenzeresulfonic acid film-coated glassy carbon electrode
    Huang, Ke-Jing
    Luo, Ding-Fa
    Xie, Wan-Zhen
    Yu, Yong-Sheng
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2008, 61 (02) : 176 - 181
  • [4] Voltammetric oxidation and determination of cinnarizine at glassy carbon electrode modified with multi-walled carbon nanotubes
    Hegde, Rajesh N.
    Hosamani, Ragunatharaddi R.
    Nandibewoor, Sharanappa T.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 72 (02) : 259 - 265
  • [5] Anodic stripping voltammetric determination of gold on a polyvinylferrocene coated glassy carbon electrode
    Kavanoz, M
    Gülce, H
    Yildiz, A
    TURKISH JOURNAL OF CHEMISTRY, 2004, 28 (03) : 287 - 297
  • [6] Trace determination of molybdenum by anodic adsorptive stripping voltammetry using a multi-walled carbon nanotubes modified carbon paste electrode
    Deng, Pei-Hong
    Fei, Jun-Jie
    Feng, Yong-Lan
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 148 (01): : 214 - 220
  • [7] Voltammetric determination of resorcinol on the surface of a glassy carbon electrode modified with multi-walled carbon nanotube
    Ghoreishi, Sayed Mehdi
    Behpour, Mohsem
    Hajisadeghian, Elahe
    Golestaneh, Mahshid
    ARABIAN JOURNAL OF CHEMISTRY, 2016, 9 : S1563 - S1568
  • [8] Voltammetric determination of bisphenol A in food package by a glassy carbon electrode modified with carboxylated multi-walled carbon nanotubes
    Junhua Li
    Daizhi Kuang
    Yonglan Feng
    Fuxing Zhang
    Mengqin Liu
    Microchimica Acta, 2011, 172 : 379 - 386
  • [9] Voltammetric determination of bisphenol A in food package by a glassy carbon electrode modified with carboxylated multi-walled carbon nanotubes
    Li, Junhua
    Kuang, Daizhi
    Feng, Yonglan
    Zhang, Fuxing
    Liu, Mengqin
    MICROCHIMICA ACTA, 2011, 172 (3-4) : 379 - 386
  • [10] Improved Voltammetric Response of Malachite Green at a Multi-Walled Carbon Nanotubes Coated Glassy Carbon Electrode in the Presence of Surfactant
    Liu, Liqin
    Zhao, Faqiong
    Xiao, Fei
    Zeng, Baizhao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (04): : 525 - 534