A new PMU based power swing detector to prevent mal-operation of distance relay

被引:4
|
作者
Ouadi A. [1 ]
Bentarzi H. [1 ]
Chafai M. [1 ]
机构
[1] Signals and Systems Laboratory, IGEE, UMBB University, Boumerdes
关键词
blinder; distance relay mal-operation; faults; phasor measurement unit; power swing detector;
D O I
10.3103/S1068371216100059
中图分类号
学科分类号
摘要
In conventional transmission line protection, a distance relay is used to provide the primary as well as remote backup protection. The voltage and current phasors measurement needed by the distance relay for determining the impedance may be affected by the power disturbances such as power swing. Consequently, this power swing may cause mal-operation of Zone three distance relays which in turn may affect on the reliability of the whole protective scheme. To mitigate these effects and hence improve the relay reliability, this work proposes a new real-time power swing detector using phasor measurement units for blinding the distance relay only during this transient disturbance. However, this developed detector will not block relay when the power swing accompanied with faults. To validate the present work, the performance of developed enhanced distance relay is tested by signals generated by Simulink/MATLAB simulator under different conditions. The test results show that this proposed scheme provides good discrimination between the transient currents and the fault current which in turn it may contribute in enhancing the reliability of Distance relay. © 2016, Allerton Press, Inc.
引用
收藏
页码:572 / 578
页数:6
相关论文
共 50 条
  • [1] Detection of power swing and prevention of mal-operation of distance relay using compressed sensing theory
    Taheri, Behrooz
    Sedighizadeh, Mostafa
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (23) : 5558 - 5570
  • [2] Scheme of the distance protection to avoid mal-operation in swing
    Li, Xiao-Bin
    Liu, Kai
    Chen, Ju-Sheng
    Xu, Gang
    Chen, Shu-Zhi
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (03): : 86 - 89
  • [3] Mal-operation analysis of phase-to-earth distance relay and its improvement
    Li, Bin
    Yao, Bin
    Fan, Ruiqing
    Li, Yongli
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (18): : 95 - 99
  • [4] The Impact of Power Swing to the Operation of Distance Relay
    Yusoff, Nooraizzat
    Abidin, Ahmad Farid
    Mahadan, Mohd Ezwan
    2015 5TH IEEE INTERNATIONAL CONFERENCE ON SYSTEM ENGINEERING AND TECHNOLOGY (ICSET), 2015, : 39 - 42
  • [5] Voltage Inversion due to Presence of SSSC on Adjacent Lines and Distance Relay Mal-Operation
    Jamali, S.
    Kazemi, A.
    Shateri, H.
    2008 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-5, 2008, : 1699 - 1704
  • [6] Voltage inversion due to presence of TCSC on adjacent lines and distance relay mal-operation
    Jamali, S.
    Kazemi, A.
    Shateri, H.
    PROCEEDINGS OF THE 41ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2006, : 809 - 813
  • [7] Distance Relay Mal-Operation Caused by Voltage Inversion Due to Presence of TCSC on Adjacent Lines
    Jamali, S.
    Kazemi, A.
    Shateri, H.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2010, 5 (05): : 2452 - 2460
  • [8] Distance relay mal-operation due to presence of SSSC on adjacent lines in inter phase faults
    Kazemi, A.
    Jamali, S.
    Shateri, H.
    2008 IEEE REGION 5 CONFERENCE, 2008, : 180 - 185
  • [9] Fast detector of symmetrical fault during power swing for distance relay
    Su, B
    Dong, XZ
    Bo, ZQ
    Sun, YZ
    Caunce, BRJ
    Tholomier, D
    Apostolov, A
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 1836 - 1841
  • [10] Voltage inversion due to presence of TCSC on adjacent lines in inter phase faults and distance relay mal-operation
    Center of Excellence for Power Systems Automation and Operation, Iran University of Science and Technology, Iran
    Proc Univ Power Eng Conf, 2008,