Electrophysiologic Characteristics of Different Ectopic Rhythms During Slow Pathway Ablation in Patients with Atrioventricular Nodal Reentrant Tachycardia

被引:0
作者
Ming-Hsiung Hsieh
Shih-Ann Chen
Ching-Tai Tai
Chern-En Chiang
Mau-Song Chang
机构
[1] National Yang-Ming University,Division of Cardiology, Department of Medicine
[2] School of Medicine,undefined
[3] and Veterans General Hospital-Taipei,undefined
来源
Journal of Interventional Cardiac Electrophysiology | 1998年 / 2卷
关键词
slow pathway; AV node; catheter ablation;
D O I
暂无
中图分类号
学科分类号
摘要
The presence of ectopic rhythm has been considered to be the most important marker for successful slow pathway ablation, but the details of different ectopic rhythms have not been well described. This study included 83 consecutive patients with typical AV node reentrant tachycardia who underwent slow pathway ablation. The interval between the atrial signals of the His bundle electrogram and the distal ablation catheter [A(H)-A(Ab)], and the interval between the atrial components of the distal ablation catheter and the ostium of coronary sinus catheter [A(Ab)-A(CSos)] were measured. One hundred episodes of ectopic rhythm occurred with 81 (81%) successful applications. There are two different origins and three activation sequences of ectopic rhythms, including HIS rhythm (78 applications, the earliest atrial activation in the His bundle electrogram), CSos rhythm (6 applications, the earliest atrial signal in the coronary sinus ostium electrogram) and CSos preceding HIS (CSos→HIS) rhythm (16 applications, the atrial activation sequences changing from CSos to HIS rhythm). The CSos rhythm had a shorter mean cycle length (445 ± 81 vs. 511 ± 132 vs. 579 ± 140 ms, p < 0.05), a shorter [A(Ab)-A(CSos)] interval (−2.5 ± 9.8 vs. 14.1 ± 11.2 vs. 12.8 ± 8.4 ms, p < 0.05) and a lower success rate (33% vs. 84% vs. 94% p < 0.05) than HIS rhythm and CSos→HIS rhythm. Otherwise, the mean cycle length of ectopic rhythm was significant shorter in successful than in failed ablation (506 ± 135 vs. 559 ± 118 ms, p = 0.04). In conclusion, we found two different origins and three activation sequences of ectopic rhythms. CSos rhythm had a lower success rate in ablation of slow pathway, thus it was a poor marker for successful ablation.
引用
收藏
页码:203 / 209
页数:6
相关论文
共 50 条
[31]   Atrioventricular nodal reentrant tachycardia ablation with radiofrequency energy during ongoing tachycardia: is it feasible? [J].
Amasyali, Basri ;
Kilic, Ayhan ;
Kabul, Kutsi ;
Unlu, Murat .
POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2014, 10 (04) :301-307
[32]   Electroanatomically estimated length of slow pathway in atrioventricular nodal reentrant tachycardia [J].
Tadanobu Irie ;
Yoshiaki Kaneko ;
Tadashi Nakajima ;
Masaki Ota ;
Takafumi Iijima ;
Mio Tamura ;
Takashi Iizuka ;
Shuntaro Tamura ;
Akihiro Saito ;
Masahiko Kurabayashi .
Heart and Vessels, 2014, 29 :817-824
[33]   Left-variant atypical atrioventricular nodal reentrant tachycardia: Electrophysiological characteristics and effect of slow pathway ablation within coronary sinus [J].
Otomo, Kiyoshi ;
Okamura, Hideo ;
Noda, Takashi ;
Satomi, Kazuhiro ;
Shimizu, Wataru ;
Suyama, Kazuhiro ;
Kurita, Takashi ;
Aihara, Naohiko ;
Kamakura, Shiro .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (11) :1177-1183
[34]   Assessment of atrioventricular nodal electrophysiological characteristics after radiofrequency catheter ablation of the slow pathway in atrioventricular nodal reentrant tachycardia - 3-month follow up [J].
Enjoji, Y ;
Sugi, K ;
Ikeda, T ;
Kasao, M ;
Noro, M ;
Sakata, T ;
Yabuki, S ;
Yamaguchi, T .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1996, 60 (11) :853-860
[35]   Using coronary sinus ostium as the reference for the slow pathway ablation of atrioventricular nodal reentrant tachycardia in children [J].
Young, Ming-Lon ;
Niu, Jianli .
JOURNAL OF ARRHYTHMIA, 2020, 36 (04) :712-719
[36]   Direct Slow Pathway Capture: A New Electrophysiological Method of Catheter Ablation for Atrioventricular Nodal Reentrant Tachycardia [J].
Matsuura, Tomomi ;
Tobiume, Takeshi ;
Takeshi, Soeki ;
Kato, Ritsushi ;
Hara, Motoki ;
Ise, Takayuki ;
Kusunose, Kenya ;
Yamaguchi, Koji ;
Yagi, Shusuke ;
Yamada, Hirotsugu ;
Wakatsuki, Tetsuzo ;
Sata, Masataka ;
Matsumoto, Kazuo .
CIRCULATION, 2017, 136
[37]   Modification of antegrade slow pathway is not crucial for successful catheter ablation of common atrioventricular nodal reentrant tachycardia [J].
Gianfranchi, L ;
Brignole, M ;
Delise, P ;
Menozzi, C ;
Paparella, N ;
Themistoclakis, S ;
Bonso, A ;
Lolli, G ;
Alboni, P .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (02) :263-267
[38]   Atrial tachycardia with slow pathway conduction mimicking typical atrioventricular nodal reentrant tachycardia [J].
Yamada, Takumi ;
Huizar, Jose F. ;
McElderry, Hugh T. ;
Kay, G. Neal .
EUROPACE, 2007, 9 (05) :299-301
[39]   Patterns of accelerated junctional rhythm during slow pathway catheter ablation for atrioventricular nodal reentrant tachycardia: Temperature dependence, prognostic value, and insights into the nature of the slow pathway [J].
Wagshal, AB ;
Crystal, E ;
Katz, A .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (03) :244-254
[40]   HISTOPATHOLOGICAL STUDY FOLLOWING CATHETER GUIDED RADIOFREQUENCY CURRENT ABLATION OF THE SLOW PATHWAY IN A PATIENT WITH ATRIOVENTRICULAR NODAL REENTRANT TACHYCARDIA [J].
GAMACHE, MC ;
BHARATI, S ;
LEV, M ;
LINDSAY, BD .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (02) :247-251