A new low-dose multi-phase trauma CT protocol and its impact on diagnostic assessment and radiation dose in multi-trauma patients

被引:22
作者
Alagic Z. [1 ]
Eriksson A. [1 ]
Drageryd E. [2 ]
Motamed S.R. [1 ]
Wick M.C. [1 ,3 ]
机构
[1] Functional Unit for Musculoskeletal Radiology, Function Imaging and Physiology, Karolinska University Hospital, Karolinska Vägen Solna, Stockholm
[2] General Electrics Healthcare Sverige AB, Danderyd
[3] Diagnostic Radiology, Institute for Molecular Medicine and Surgery (MMK), Karolinska Institutet, Stockholm
关键词
ASIR-V; CT protocol; Missed injuries; Radiation dose; Trauma CT; Whole-body CT angiography;
D O I
10.1007/s10140-017-1496-4
中图分类号
学科分类号
摘要
Purpose: Computed tomography (CT) examinations, often using high-radiation dosages, are increasingly used in the acute management of polytrauma patients. This study compares a low-dose polytrauma multi-phase whole-body CT (WBCT) protocol on a latest generation of 16-cm detector 258-slice multi-detector CT (MDCT) scanner with advanced dose reduction techniques to a single-phase polytrauma WBCT protocol on a 64-slice MDCT scanner. Methods: Between March and September 2015, 109 polytrauma patients (group A) underwent acute WBCT with a low-dose multi-phase WBCT protocol on a 258-slice MDCT whereas 110 polytrauma patients (group B) underwent single-phase trauma CT on a 64-slice MDCT. The diagnostic accuracy to trauma-related injuries, radiation dose, quantitative and semiquantitative image quality parameters, subjective image quality scorings, and workflow time parameters were compared. Results: In group A, statistically significantly more arterial injuries (p = 0.04) and arterial dissections (p = 0.002) were detected. In group A, the mean (±SD) dose length product value was 1681 ± 183 mGy*cm and markedly lower when compared to group B (p < 0.001). The SDs of the mean Houndsfield unit values of the brain, liver, and abdominal aorta were lower in group A (p < 0.001). Mean signal-to-noise ratios (SNRs) for the brain, liver, and abdominal aorta were significantly higher in group A (p < 0.001). Group A had significantly higher image quality scores for all analyzed anatomical locations (p < 0.02). However, the mean time from patient registration until completion of examination was significantly longer for group A (p < 0.001). Conclusions: The low-dose multi-phase CT protocol improves diagnostic accuracy and image quality at markedly reduced radiation. However, due to technical complexities and surplus electronic data provided by the newer low-dose technique, examination time increases, which reduces workflow in acute emergency situations. © 2017, The Author(s).
引用
收藏
页码:509 / 518
页数:9
相关论文
共 25 条
  • [1] (2012)
  • [2] Linsenmaier U., Reiser M., Multislice computed tomography in emergency radiology, Radiologe, 49, 6, pp. 479-480, (2009)
  • [3] Leidner B., Adiels M., Aspelin P., Gullstrand P., Wallen S., Standardized CT examination of the multitraumatized patient, Eur Radiol, 8, 9, pp. 1630-1638, (1998)
  • [4] Linsenmaier U., Krotz M., Hauser H., Rock C., Rieger J., Bohndorf K., Pfeifer K.J., Reiser M., Whole-body computed tomography in polytrauma: techniques and management, Eur Radiol, 12, 7, pp. 1728-1740, (2002)
  • [5] Romano L., Scaglione M., Rotondo A., Emergency radiology today between philosophy of science and the reality of “emergency care, Radiol Med, 111, 2, pp. 245-251, (2006)
  • [6] Wintermark M., Poletti P.A., Becker C.D., Schnyder P., Traumatic injuries: organization and ergonomics of imaging in the emergency environment, Eur Radiol, 12, 5, pp. 959-968, (2002)
  • [7] Hajibandeh S., Hajibandeh S., Systematic review: effect of whole-body computed tomography on mortality in trauma patients, J Inj Violence Res, 7, 2, pp. 64-74, (2015)
  • [8] Ptak T., Rhea J.T., Novelline R., Radiation dose is reduced with a single-pass whole-body multi–detector row CT trauma protocol compared with a conventional segmented method: initial experience, Radiology, 229, pp. 902-905, (2003)
  • [9] Linder F., Mani K., Juhlin C., Eklof H., Routine whole body CT of high energy trauma patients leads to excessive radiation exposure, Scand J Trauma Resusc Emerg Med, 24, (2016)
  • [10] Pauwels E.K., Bourguignon M.H., Radiation dose features and solid cancer induction in pediatric computed tomography, Med Princ Pract, 21, 6, pp. 508-515, (2012)