Wireless non-invasive continuous respiratory monitoring with FMCW radar: a clinical validation study

被引:0
作者
K. van Loon
M. J. M. Breteler
L. van Wolfwinkel
A. T. Rheineck Leyssius
S. Kossen
C. J. Kalkman
B. van Zaane
L. M. Peelen
机构
[1] University Medical Center Utrecht,Department of Anesthesiology
[2] ZGT Hospital,Department of Intensive Care
[3] Radar Technology at TNO,Julius Center for Health Sciences and Primary Care
[4] University Medical Center Utrecht,undefined
来源
Journal of Clinical Monitoring and Computing | 2016年 / 30卷
关键词
Radar; Respiratory rate; Monitoring; Remote;
D O I
暂无
中图分类号
学科分类号
摘要
Altered respiratory rate is one of the first symptoms of medical conditions that require timely intervention, e.g., sepsis or opioid-induced respiratory depression. To facilitate continuous respiratory rate monitoring on general hospital wards a contactless, non-invasive, prototype monitor was developed using frequency modulated continuous wave radar. We aimed to study whether radar can reliably measure respiratory rate in postoperative patients. In a diagnostic cross-sectional study patients were monitored with the radar and the reference monitor (pneumotachograph during mechanical ventilation and capnography during spontaneous breathing). Eight patients were included; yielding 796 min of observation time during mechanical ventilation and 521 min during spontaneous breathing. After elimination of movement artifacts the bias and 95 % limits of agreement for mechanical ventilation and spontaneous breathing were −0.12 (−1.76 to 1.51) and −0.59 (−5.82 to 4.63) breaths per minute respectively. The radar was able to accurately measure respiratory rate in mechanically ventilated patients, but the accuracy decreased during spontaneous breathing.
引用
收藏
页码:797 / 805
页数:8
相关论文
共 74 条
[1]  
Hillman K(2001)Antecedents to hospital deaths Intern Med J 31 343-348
[2]  
Bristow P(1994)Developing strategies to prevent inhospital cardiac arrest: analyzing responses of physicians and nurses in the hours before the event Crit Care Med 22 244-247
[3]  
Chey T(1999)Physiological values and procedures in the 24 h before ICU admission from the ward Anaesthesia 54 529-534
[4]  
Daffurn K(2004)Association between clinically abnormal observations and subsequent in-hospital mortality: a prospective study Resuscitation 62 137-141
[5]  
Jacques T(1993)Respiratory rate predicts cardiopulmonary arrest for internal medicine inpatients J Gen Intern Med 8 354-360
[6]  
Norman SL(2007)Can physiological variables and early warning scoring systems allow early recognition of the deteriorating surgical patient? Crit Care Med 35 402-409
[7]  
Franklin C(2011)Nursing documentation prior to emergency admissions to the intensive care unit Nurs Crit Care 16 164-169
[8]  
Mathew J(2005)Long-term effect of introducing an early warning score on respiratory rate charting on general wards Resuscitation 65 41-44
[9]  
Goldhill DR(2009)Nurses’ role in detecting deterioration in ward patients: systematic literature review J Adv Nurs 65 1992-2006
[10]  
White SA(1999)Council recommendation of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) Off J Eur Communities L 199 59-70