Effects of 660- and 980-nm low-level laser therapy on neuropathic pain relief following chronic constriction injury in rat sciatic nerve

被引:0
作者
M. Masoumipoor
S. B. Jameie
A. Janzadeh
F. Nasirinezhad
M. Soleimani
M. Kerdary
机构
[1] Islamic Azad University,Department of Nuclear Engineering, Sciences and Researches Branch
[2] IUMS,Department of Medical Basic Sciences, Faculty of Allied Medicine
[3] IUMS,Department of Anatomy, Faculty of Medicine
[4] IUMS,Research Center of Physiology, Faculty of Medicine
来源
Lasers in Medical Science | 2014年 / 29卷
关键词
Low-level laser therapy; CCI; Neuropathic pain;
D O I
暂无
中图分类号
学科分类号
摘要
Neuropathic pain (NP) is one of the most suffered conditions in medical disciplines. The role of reactive oxygen species (ROS) and oxidative stress in the induction of NP was studied by many researchers. Neuropathies lead to medical, social, and economic isolation of the patient, so various therapies were used to treat or reduce it. During the recent years, low-level laser therapy (LLLT) has been used in certain areas of medicine and rehabilitation. Chronic constriction injury (CCI) is a well-known model for neuropathic pain studies. In order to find the effects of different wavelengths of LLLT on the injured sciatic nerve, the present research was done. Thirty Wistar adult male rats (230–320 g) were used in this study. The animals were randomly divided into three groups (n = 10). To induce neuropathic pain for the sciatic nerve, the CCI technique was used. Low-level laser of 660 and 980 nm was used for two consecutive weeks. Thermal and mechanical hyperalgesia was done before and after surgery on days 7 and 14, respectively. Paw withdrawal thresholds were also evaluated. CCI decreased the pain threshold, whereas both wavelengths of LLLT for 2 weeks increased mechanical and thermal threshold significantly. A comparison of the mechanical and thermal threshold showed a significant difference between the therapeutic effects of the two groups that received LLLT. Based on our findings, the laser with a 660-nm wavelength had better therapeutic effects than the laser with a 980-nm wavelength, so the former one may be used for clinical application in neuropathic cases; however, it needs more future studies.
引用
收藏
页码:1593 / 1598
页数:5
相关论文
共 236 条
  • [1] WangLX WZJ(2003)Animal and cellular models of chronic pain Adv Drug Deliv Rev 55 949-965
  • [2] WoolfCJ MRJ(1999)Neuropathic pain: aetiology, symptoms, mechanisms, and management Lancet 353 1959-1964
  • [3] Zimmermann M(2001)Pathobiology of neuropathic pain Eur J Pharmacol 429 23-37
  • [4] Woolf CJ(1996)Windup and central sensitization are not equivalent Pain 66 105-108
  • [5] Bennett GJ(1988)A peripheral mononeuropathy in rat that produces disorders of pain sensation like those seen in man Pain 33 87-107
  • [6] Xie YK(2003)Models of neuropathic pain in the rat Current Protocols in Pharmacology 72 74-79
  • [7] Gary J(1941)A method for determining loss of pain sensation J Pharmacol Exp Ther 32 77-88
  • [8] Bennett G(1988)A new and sensitive method for measuring thermal nociception in cutaneous hyperalgesia Pain 56 171-176
  • [9] Chung JM(1993)Structure of the rat's behaviour in the hot plate test Behav Brain Res 80 300-307
  • [10] Honore M(1944)The evaluation of the anelgesic action of pethidine hydrochloride (Dermol) J. Pharmacol. Exp. Ther 53 55-63