Verifying institutionally developed hybrid 3D-printed coaxial cylindrical phantom for patient-specific quality assurance in stereotactic body radiation therapy of hepatocellular carcinoma

被引:0
作者
M. P. Arun Krishnan
M. Ummal Momeen
机构
[1] Vellore Institute of Technology,School of Advanced Sciences
[2] MVR Cancer Centre and Research Institute,undefined
来源
Radiological Physics and Technology | 2024年 / 17卷
关键词
Patient specific quality assurance; Stereotactic body radiation therapy; Hepatocellular carcinoma; Hybrid 3D-printed hybrid coaxial cylindrical phantom;
D O I
暂无
中图分类号
学科分类号
摘要
An accurate and reliable patient-specific quality assurance (PSQA) is crucial to ensure the safety and precision of Stereotactic body radiation therapy (SBRT) in treating Hepatocellular carcinoma (HCC). This study examines the effectiveness of a novel hybrid 3D-printed hybrid coaxial cylindrical phantom for PSQA in the SBRT of HCC. The study compared three different point dose verification techniques for PSQA: a traditional solid water phantom, two dimensional detector array I’MatriXX, and a newly developed hybrid 3D-printed phantom. Thirty SBRT HCC liver cases were examined using these techniques, and point doses were measured and compared to planned doses using the perpendicular composite method with solid water and I’MatriXX phantoms. Unlike the other two methods, the point dose was compared in true composite geometry using the hybrid 3D-printed phantom, which enhanced the accuracy and consistency of PSQA. The study aims to assess the statistical significance and accuracy of the hybrid 3D-printed phantom compared to other methods. The results showed all techniques complied with the institutional threshold criteria of within ± 3% for point-dose measurement discrepancies. The hybrid 3D-printed phantom was found to have better consistency with a lower standard deviation than traditional methods. Statistical analysis using Student’s t-test revealed the statistical significance of the hybrid 3D-printed phantom technique in patient-specific point-dose assessments with a p-value < 0.01. The hybrid 3D-printed phantom developed institutionally is cost-effective and easy to handle. It has been proven to be a valuable tool for PSQA in SBRT for the treatment of HCC and has demonstrated its practicality and reliability.
引用
收藏
页码:230 / 237
页数:7
相关论文
共 31 条
[1]  
Rumgay H(2022)Global, regional and national burden of primary liver cancer by subtype Eur J Cancer 161 108-118
[2]  
Rao PN(2023)The changing epidemiology of hepatocellular carcinoma! Indian J Gastroenterol 14 4383-8
[3]  
Kulkarni AV(2022)The current role of stereotactic body radiation therapy (SBRT) in hepatocellular carcinoma (HCC) Cancers 10 347-373
[4]  
Kimura T(2020)Stereotactic body radiation therapy vs transarterial chemoembolization in inoperable barcelona clinic liver cancer stage a hepatocellular carcinoma: a retrospective, propensity-matched analysis Front Oncol 12 1-1032
[5]  
Su T-S(2017)Stereotactic body radiation therapy (SBRT) for definitive treatment and as a bridge to liver transplantation in early stage inoperable Hepatocellular carcinoma Radiat Oncol 31 365-14
[6]  
Moore A(2019)Stereotactic body radiotherapy for small unresectable hepatocellular carcinomas Clin Oncol 92 20181053-4101
[7]  
Yeung R(2019)Stereotactic body radio therapy for inoperable large hepatocellular cancers: results from a clinical audit Br J Radiol 60 1026-2115
[8]  
Chopra S(2004)American Society for Therapeutic Radiology and Oncology* and American College of Radiology Practice Guideline for the performance of stereotactic body radiation therapy Int J Radiat Oncol Biol Phys 14 1-661
[9]  
Potters L(2019)Prediction of VMAT delivery accuracy with textural features calculated from fluence maps Radiat Oncol 37 4078-2464
[10]  
Park JM(2010)Stereotactic body radiation therapy: the report of AAPM Task Group 101 Med Phys 30 2089-459