Blood pressure differences between a mercury sphygmomanometer and two automatic devices

被引:0
|
作者
Lim H.K. [1 ,2 ]
Doh I. [1 ]
Ahn B. [1 ,2 ]
机构
[1] Korea Research Institute of Standards and Science, Seoul
[2] Korea University of Science and Technology, Seoul
关键词
Blood pressure; Cardiovascular disease; Measurement; Reference; Sphygmomanometer;
D O I
10.1007/s13534-015-0207-x
中图分类号
学科分类号
摘要
Purpose: Blood pressure (BP) is one of the most important pieces of information to diagnose cardiovascular diseases but the measurement readings could be easily changed by various factors. If these readings are wrong, it may ultimately lead to a misdiagnosis. In addition, there is a problem when there are different devices used to read blood pressure because these devices may give different readings. Methods: Four different BP measurement devices were used, including two mercury sphygmomanometers and two automatic digital devices. Thirty-eight healthy young people (mean age = 27.1±6.1 years) stayed one night at a clinical center and the BPs were measured from their right arms on the following day. Factors such as exercise, food, and smoking that may affect the BP were controlled and prohibited. All tests were repeated three times and all devices were calibrated before the test. Absolute BP value difference between a mercury sphygmomanometer and an automatic digital device was counted for the BP difference between devices ≥ 5 mmHg and ≥ 10 mmHg of each measurement. Results: Significant inter-device BP differences were found between a mercury sphygmomanometer and two automatic devices (p<0.01) while no significant difference was found between mercury sphygmomanometers (p>0.5); all subjects showed BP difference less than 5 mmHg between two mercury sphygmomanometers while only 32% and 38% of subjects showed BP difference less than 5 mmHg for two out of three repeated tests between a mercury sphygmomanometer and an automatic device, and even 26% ~ 36% of subjects showed BP difference ≥ 10 mmHg. Conclusions: This study result stresses that it is necessary to check the reliability of automatic blood pressure devices used in the hospitals. In addition, an easier and more convenient protocol should be developed for the routine calibration of automatic devices. © 2015, Korean Society of Medical and Biological Engineering and Springer.
引用
收藏
页码:296 / 301
页数:5
相关论文
共 50 条
  • [21] Age-Specific Differences Between Conventional and Ambulatory Daytime Blood Pressure Values
    Conen, David
    Aeschbacher, Stefanie
    Thijs, Lutgarde
    Li, Yan
    Boggia, Jose
    Asayama, Kei
    Hansen, Tine W.
    Kikuya, Masahiro
    Bjorklund-Bodegard, Krishna
    Ohkubo, Takayoshi
    Jeppesen, Jorgen
    Gu, Yu-Mei
    Torp-Pedersen, Christian
    Dolan, Eamon
    Kuznetsova, Tatiana
    Stolarz-Skrzypek, Katarzyna
    Tikhonoff, Valerie
    Schoen, Tobias
    Malyutina, Sofia
    Casiglia, Edoardo
    Nikitin, Yuri
    Lind, Lars
    Sandoya, Edgardo
    Kawecka-Jaszcz, Kalina
    Mena, Luis
    Maestre, Gladys E.
    Filipovsky, Jan
    Imai, Yutaka
    O'Brien, Eoin
    Wang, Ji-Guang
    Risch, Lorenz
    Staessen, Jan A.
    HYPERTENSION, 2014, 64 (05) : 1073 - +
  • [22] Ethnicity and Differences Between Clinic and Ambulatory Blood Pressure Measurements
    Martin, Una
    Haque, M. Sayeed
    Wood, Sally
    Greenfield, Sheila M.
    Gill, Paramjit S.
    Mant, Jonathan
    Mohammed, Mohammed A.
    Heer, Gurdip
    Johal, Amanpreet
    Kaur, Ramendeep
    Schwartz, Claire
    McManus, Richard J.
    AMERICAN JOURNAL OF HYPERTENSION, 2015, 28 (06) : 729 - 738
  • [23] Comparison of Dinamap 8100 with sphygmomanometer blood pressure measurement in a prepubertal diabetes cohort
    Jin, RZ
    Donaghue, KC
    Fairchild, JM
    Chan, A
    Silink, M
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2001, 37 (06) : 545 - 549
  • [24] Blood pressure differences between patients with lacunar and nonlacunar infarcts
    Altmann, Marianne
    Thommessen, Bente
    Ronning, Ole Morten
    Reichenbach, Antje S.
    Fure, Brynjar
    BRAIN AND BEHAVIOR, 2015, 5 (08):
  • [25] Relationship between mercury in blood and 24-h ambulatory blood pressure in Greenlanders and Danes
    Pedersen, EB
    Jorgensen, ME
    Pedersen, MB
    Siggaard, C
    Sorensen, TB
    Mulvad, G
    Hansen, JC
    Asmund, G
    Skjoldborg, H
    AMERICAN JOURNAL OF HYPERTENSION, 2005, 18 (05) : 612 - 618
  • [26] The relationship between change blood pressure, blood pressure and time
    Harrison, MJ
    Kluger, MT
    Robertson, NN
    ANAESTHESIA, 2000, 55 (04) : 385 - 387
  • [27] Relationship between mercury concentration in blood, cognitive performance, and blood pressure, in an elderly urban population
    Johansson, N
    Basun, H
    Winblad, B
    Nordberg, M
    BIOMETALS, 2002, 15 (02) : 189 - 195
  • [28] Relationship between mercury concentration in blood, cognitive performance, and blood pressure, in an elderly urban population
    Nina Johansson
    Hans Basun
    Bengt Winblad
    Monica Nordberg
    Biometals, 2002, 15 : 189 - 195
  • [29] The impact of blood pressure measurement methods on the assessment of differences in blood pressure levels between patients with normoalbuminuric type 1 diabetes and healthy controls
    G Vervoort
    JFM Wetzels
    JA Lutterman
    JHM Berden
    Th Thien
    P Smits
    Journal of Human Hypertension, 1999, 13 : 117 - 122
  • [30] The impact of blood pressure measurement methods on the assessment of differences in blood pressure levels between patients with normoalbuminuric type 1 diabetes and healthy controls
    Vervoort, G
    Wetzels, JFM
    Lutterman, JA
    Berden, JHM
    Thien, T
    Smits, P
    JOURNAL OF HUMAN HYPERTENSION, 1999, 13 (02) : 117 - 122