Feasibility of pulse combustion in micro gas turbines

被引:0
作者
Juha Honkatukia
Esa Saari
Timo Knuuttila
Jaakko Larjola
Jari Backman
机构
[1] Lappeenranta University of Technology,
[2] T-Turbine Oy,undefined
来源
Journal of Thermal Science | 2012年 / 21卷
关键词
Gas turbine; pulse combustion; micro size; low Reynolds number;
D O I
暂无
中图分类号
学科分类号
摘要
In gas turbines, a fast decrease of efficiency appears when the output decreases; the efficiency of a large gas turbine (20...30 MW) is in the order of 40 %, the efficiency of a 30 kW gas turbine with a recuperator is in the order of 25 %, but the efficiency of a very small gas turbine (2...6 kW) in the order of 4...6 % (or 8...12 % with an optimal recuperator). This is mainly a result of the efficiency decrease in kinetic compressors, due to the Reynolds number effect. Losses in decelerating flow in a flow passage are sensitive to the Reynolds number effects. In contrary to the compression, the efficiency of expansion in turbines is not so sensitive to the Reynolds number; very small turbines are made with rather good efficiency because the flow acceleration stabilizes the boundary layer. This study presents a system where the kinetic compressor of a gas turbine is replaced with a pulse combustor. The combustor is filled with a combustible gas mixture, ignited, and the generated high pressure gas is expanded in the turbine. The process is repeated frequently, thus producing a pulsating flow to the turbine; or almost a uniform flow, if several parallel combustors are used and triggered alternately in a proper way. Almost all the compression work is made by the temperature increase from the combustion. This gas turbine type is investigated theoretically and its combustor also experimentally with the conclusion that in a 2 kW power size, the pulse flow gas turbine is not as attractive as expected due to the big size and weight of parallel combustors and due to the efficiency being in the order of 8 % to 10 %. However, in special applications having a very low power demand, below 1000 W, this solution has better properties when compared to the conventional gas turbine and it could be worth of a more detailed investigation.
引用
收藏
页码:466 / 473
页数:7
相关论文
共 3 条
[1]  
Lampinen M. J.(1992)Thermodynamic analysis of a pulse combustion system and its application to gas turbines International Journal of Energy Research 16 259-276
[2]  
Turunen R.(undefined)undefined undefined undefined undefined-undefined
[3]  
Köykkä M.(undefined)undefined undefined undefined undefined-undefined