Our objective was to examine factors that affect the accuracy of energy expenditure measurements (EE), when using flow-through indirect calorimetry (IC), to determine the minimum length of time needed to measure 24- and 48-h EE and to compare cross-over and parallel designs as methods of investigation during energy balance collections (EB) in preterm infants. A baby doll manikin was used to determine equilibration times and to compare VCO2 and VO2 as measured by flow meter and indirect calorimetry under different study conditions, one of which simulated an EB. “Continuous” EE was measured to determine the minimum length of time needed to accurately reflect 24- and 48-h EE and to compare parallel and cross-over studies as methods of study design in a group of “normal” enterally fed preterm infants. The mean (±SD) errors between flow meter and indirect calorimetry determinations for VCO2 and VO2 were −1.9 ± 2.5 and −1.8 ± 4.3% under conditions that simulated an EB. Cumulative 6-h EE accurately predicted 24- and 48-h EE. Expressed in absolute terms (kcal/d), EE did not change on a day-to-day basis but did increase over the 2-wk study period. Expressed on body weight basis (kcal/kg/d), EE did not change on a day-to-day or week-to-week basis. The variance in EE due to biologic variability;i.e. the parallel design, was ∼6 times greater than that due to age, weight, and weight gain;i.e. the cross-over design. Indirect calorimetry, therefore, accurately measures EE in conditions simulating an energy balance collection. Six-hour EE determinations are valid estimate of EE during a 48-h balance collection, while cross-over studies may be the preferred method of study design during short-term studies of EE in preterm infants.
引用
收藏
页码:518 / 523
页数:5
相关论文
共 50 条
  • [41] Measurement of energy expenditure
    Levine, JA
    PUBLIC HEALTH NUTRITION, 2005, 8 (7A) : 1123 - 1132
  • [42] Measurement of Energy Expenditure
    DeLany, James P.
    PEDIATRIC BLOOD & CANCER, 2012, 58 (01) : 129 - 134
  • [43] Factors Associated With Energy Expenditure and Energy Balance in Acute Sport-Related Concussion
    Walton, Samuel Richard
    Kranz, Sibylle
    Malin, Steven Kenneth
    Broshek, Donna K.
    Hertel, Jay
    Resch, Jacob Earl
    JOURNAL OF ATHLETIC TRAINING, 2021, 56 (08) : 860 - 868
  • [44] Energy expenditure and plasma catecholamines in preterm infants with mild chronic lung disease
    Bauer, J
    Maier, K
    Muehlbauer, B
    Poeschl, J
    Linderkamp, O
    EARLY HUMAN DEVELOPMENT, 2003, 72 (02) : 147 - 157
  • [45] ENERGY-EXPENDITURE OF PRETERM INFANTS AS DETERMINED BY SIMULTANEOUS DIRECT AND INDIRECT CALORIMETRY
    BELL, EF
    MEIS, SJ
    JOHNSON, KJ
    GLATZLHAWLIK, MA
    DOVE, EL
    PEDIATRIC RESEARCH, 1990, 28 (03) : 301 - 301
  • [46] Changes in Energy Expenditure in Preterm Infants During Weaning: A Randomized Comparison of Two Weaning Methods from an Incubator
    Valentin Weintraub
    Francis B Mimouni
    Shaul Dollberg
    Pediatric Research, 2007, 61 : 341 - 344
  • [47] Changes in energy expenditure in preterm infants during weaning: A randomized comparison of two weaning methods from an incubator
    Weintraub, Valentin
    Mimouni, Francis B.
    Dollberg, Shaul
    PEDIATRIC RESEARCH, 2007, 61 (03) : 341 - 344
  • [48] RE: Factors affecting occipito-frontal circumference measurement in preterm infants
    Chakkarapani, Elavazhagan
    Rogahn, Detlev
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2008, 44 (04) : 236 - 236
  • [49] Direct measurement of energy expenditure of physical activity in premature infants.
    Thureen, PJ
    DeMarie, MP
    Phillips, RE
    Hay, WW
    PEDIATRIC RESEARCH, 1996, 39 (04) : 1910 - 1910
  • [50] A GRADIENT-LAYER CALORIMETER FOR MEASUREMENT OF ENERGY-EXPENDITURE OF INFANTS
    MEIS, SJ
    DOVE, EL
    BELL, EF
    THOMPSON, CM
    GLATZLHAWLIK, MA
    GANTS, AL
    KIM, WK
    AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 266 (03): : R1052 - R1060