Predicting effect factors of dual bag filter system for PCDD/Fs removal from hazardous waste incineration flue gas

被引:0
作者
Yanan Li
Qi Liu
Minghui Tang
Fei Wang
Shengyong Lu
Makwarimba Chengetai Portia
Yong Chi
机构
[1] Zhejiang University,State Key Laboratory of Clean Energy Utilization, Institute for Thermal Power Engineering
来源
Waste Disposal & Sustainable Energy | 2023年 / 5卷
关键词
PCDD/Fs removal; Hazardous waste; Activated carbon; Dual  bag filter; Removal efficiency model;
D O I
暂无
中图分类号
学科分类号
摘要
The dual  bag filter (DBF) system is a new polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) emission control technology that has more efficient (PCDD/Fs) removal performance,  a higher activated carbon utilization rate and less activated carbon consumption compared with the traditional single bag filter system. Moreover, few studies have been relevant to the mechanism of the PCDD/Fs removal process in the DBF system, and the selection of operating conditions of the DBF system lacks an academic basis. This study established a PCDD/Fs removal efficiency model of activated carbon injection combined bag filter (ACI+DBF) system for hazardous waste incineration flue gas and predicted  the crucial effect factors. New adsorption coefficients k1=532,145 Nm3/(mol s) and k2=45 Nm3/(mol s), and the relationship expression between the number of available adsorption positions of recycled AC (AAC′) and cycle times (n) are proposed in the model. The results verify that the model error was below 5%. In addition, the PCDD/Fs removal efficiency model predicts that in a certain range, the PCDD/Fs removal efficiency increases with increasing activated carbon injection concentration. The best cycle number of activated carbon was less than 3, and the ratio of circulating activated carbon to fresh activated carbon in second bag filter (SBF) should be controlled at 7–8.
引用
收藏
页码:177 / 187
页数:10
相关论文
共 85 条
[1]  
Wu S(2015)Inhibiting evaporation of heavy metal by controlling its chemical speciation in MSWI fly ash Fuel 158 764-769
[2]  
Xu Y(1995)On the mechanisms of dioxin formation in combustion processes Chemosphere 31 4099-4117
[3]  
Sun J(2015)A review of dioxin-related substances during municipal solid waste incineration Waste Management 36 106-118
[4]  
Huang H(2003)Effect of chlorine content in feeding wastes of incineration on the emission of polychlorinated dibenzo-p-dioxins/dibenzofurans Science of The Total Environment. 302 185-198
[5]  
Buekens A(2009)Emissions of PCDD/Fs from municipal solid waste incinerators in China Chemosphere 75 1153-1158
[6]  
Zhou H(2009)Stack gas emissions of PCDD/Fs from hospital waste incinerators in China Chemosphere 77 634-639
[7]  
Meng A(2007)Removal characteristics of PCDDs/Fs from municipal solid waste incinerator by dual bag filter (DBF) system Fuel 86 813-819
[8]  
Long Y(2008)Removal characteristics of PCDD/Fs by the dual bag filter system of a fly ash treatment plant Journal of Hazardous Materials. 153 1015-1022
[9]  
Lin-Chi W(2008)Reduction of dioxin-like compound emissions from a Waelz plant with adsorbent injection and a dual baghouse filter system Environmental Science & Technology. 42 2111-2117
[10]  
Wen-Jhy L(2009)Minimum feeding rate of activated carbon to control dioxin emissions from a large-scale municipal solid waste incinerator Journal of Hazardous Materials. 161 1436-1443