Major dehiscence of infected aortic valve prosthesis with “rocking motion” but without diastolic paravalvular regurgitation

被引:0
作者
Ethel Metz
Marc Hartmann
Clemens von Birgelen
Max M. P. Haalebos
Patrick M. J. Verhorst
机构
[1] Medisch Spectrum Twente,Department of Cardiology
[2] Thoraxcentrum Twente,Department of Cardiovascular Surgery
[3] Medisch Spectrum Twente,undefined
[4] Thoraxcentrum Twente,undefined
来源
The International Journal of Cardiovascular Imaging | 2006年 / 22卷
关键词
Endocarditis; Prosthetic valve; Rocking motion; Transesophageal echocardiography;
D O I
暂无
中图分类号
学科分类号
摘要
We present a case of a 66-year-old patient with infective endocarditis of an aortic valve bioprosthesis with major dehiscence and extensive “rocking motion” but without any diastolic paravalvular regurgitation as assessed with radiography and transesophageal echocardiography.
引用
收藏
页码:771 / 774
页数:3
相关论文
共 60 条
[1]  
Arnett EN(1976)Prosthetic valve endocarditis: clinicopathologic analysis of 22 necropsy patients with comparison observations in 74 necropsy patients with active infective endocarditis involving natural left-sided cardiac valves Am J Cardiol 38 281-292
[2]  
Roberts WC(1996)Clinical outcome and echocardiographic findings of native and prosthetic valve endocarditis in the 1990’s Eur Heart J 17 281-288
[3]  
Schulz R(2001)Prosthetic valve endocarditis Heart 85 590-593
[4]  
Werner GS(1993)Comparison of transthoracic and transesophageal echocardiography for detection of abnormalities of prosthetic and bioprosthetic valves in the mitral and aortic positions Am J Cardiol 71 210-215
[5]  
Fuchs JB(1994)Clinical impact of transesophageal echocardiography in the diagnosis and management of infective endocarditis Am J Cardiol 73 1089-1091
[6]  
Andreas S(1993)Implication of negative results on a monoplane transesophageal echocardiographic study in patients with suspected infective endocarditis J Am Coll Cardiol 21 216-221
[7]  
Prange H(2004)Guidelines on prevention, diagnosis and treatment of infective endocarditis executive summary; the task force on infective endocarditis of the European Society of Cardiology Eur Heart J 25 267-276
[8]  
Riscjewsi W(1993)Frequency of ring abscess and cuspal infection in active infective endocarditis involving bioprosthetic valves Am J Cardiol 72 314-323
[9]  
Piper C(1983)Two-dimensional echocardiographic assessment of bioprosthetic valve dysfunction and infective endocarditis J Am Coll Cardiol 2 597-606
[10]  
Körfer R(1981)Two-dimensional echographic observations in major detachment of a prosthetic aortic valve Am Heart J 101 231-233