Analytical procedure for the determination of very volatile organic compounds (C3–C6) in indoor air

被引:0
作者
Alexandra Schieweck
Jan Gunschera
Deniz Varol
Tunga Salthammer
机构
[1] Fraunhofer Wilhelm-Klauditz-Institut,Department of Material Analysis and Indoor Chemistry
来源
Analytical and Bioanalytical Chemistry | 2018年 / 410卷
关键词
VVOC; Indoor air; Analysis; Gas chromatography; Mass spectrometry; Thermal desorption;
D O I
暂无
中图分类号
学科分类号
摘要
The substance group of very volatile organic compounds (VVOCs) is moving into the focus of indoor air analysis, facing ongoing regulations at international and European levels targeting on indoor air quality and human health. However, there exists at present no validated analysis for the identification and quantification of VVOCs in indoor air. Therefore, the present study targeted on the development of an analytical method in order to sample the maximum possible quantity of VVOCs in indoor air on solid sorbents with subsequent analysis by thermal desorption and coupled gas chromatography/mass spectrometry (TDS-GC/MS). For this purpose, it was necessary to investigate the performance of available sorbents and to optimize the parameters of GC/MS analysis. Stainless steel tubes filled with Carbograph 5TD were applied successfully for low-volume sampling (2–4 l) with minimal breakthrough (< 1%). With the developed method, VVOCs between C3 and C6 of different volatility and polarity  can be detected even in trace quantities with low limits of quantitation (LOQ; 1–3 μg m−3). Limitations occur for low molecular weight compounds ≤C3, especially for polar substances, such as carboxylic acids and for some aldehydes and alcohols. Consequently, established methods for the quantification of these compounds in indoor air cannot be fully substituted yet. At least three different analytical techniques are needed to cover the large spectrum of relevant VVOCs in indoor air. In addition, unexpected reaction products might occur and need to be taken into account to avoid misinterpretation of chromatographic signals.
引用
收藏
页码:3171 / 3183
页数:12
相关论文
共 92 条
  • [1] Logue JM(2011)Hazard assessment of chemical air contaminants measured in residences Indoor Air 21 92-109
  • [2] McKone TE(2013)Airborne molds and bacteria, microbial volatile organic compounds (MVOC), plasticizers and formaldehyde in dwellings in three North European cities in relation to sick building syndrome (SBS) Sci Total Environ 444 433-440
  • [3] Sherman MH(2012)Identification of volatile markers for indoor fungal growth and chemotaxonomic classification of Aspergillus species Fungal Biol 116 941-953
  • [4] Singer BC(2018)Sensory evaluation and chemical analysis of exhaled and dermally emitted bioeffluents Indoor Air 28 146-163
  • [5] Sahlberg B(2016)Analysis of odour compounds from scented consumer products using gas chromatography-mass spectrometry and gas chromatography-olfactometry Anal Chim Acta 904 98-106
  • [6] Gunnbjörnsdottir M(2016)Very volatile organic compounds: an understudied class of indoor air pollutants Indoor Air 26 25-38
  • [7] Soon A(2016)Sampling methods of emerging organic contaminants in indoor air Trends Anal Chem 12 13-22
  • [8] Jogi R(2010)Sorbent-based sampling methods for volatile and semi-volatile organic compounds in air. Part 1: Sorbent-based air monitoring options J Chromatogr A 1217 2674-2684
  • [9] Gislason T(2010)Sorbent-based sampling methods for volatile and semi-volatile organic compounds in air. Part 2: Sorbent selection and other aspects of optimizing air monitoring methods J Chromatogr A 1217 2685-2694
  • [10] Wieslander G(2000)Stability of reactive low boiling hydrocarbons on carbon based adsorbents typically used for adsorptive enchrichment and thermal desorption Fresenius J Anal Chem 366 70-78