Non-invasive glucose measuring apparatus based on conservation of energy method

被引:0
作者
Zhen-cheng Chen
Xing-liang Jin
Jian-ming Zhu
Di-ya Wang
Ting-ting Zhang
机构
[1] Central South University,School of Info
来源
Journal of Central South University of Technology | 2009年 / 16卷
关键词
single chip; non-invasive measurement; blood glucose; conservation of energy method;
D O I
暂无
中图分类号
学科分类号
摘要
A new non-invasive blood glucose measuring apparatus (NBGMA) made up of MSP430F149 SCM (single chip micyoco) was developed, which can measure blood glucose level (BGL) frequently, conveniently and painlessly. The hardware and software of this apparatus were designed, and detecting algorithms based on conservation of energy method (COEM) were presented. According to the law of conservation of energy that the energy derived by human body equals energy consumed by metabolism, and the relationship between convection, evaporation, radiation and the BGL was established. The sensor module was designed. 20 healthy volunteers were involved in the clinical experiment. The BGL measured by an automatic biochemical analyzer (ABA) was set as the reference. Regression analysis was performed to compare the conservation of energy method with the biochemical method, using the 20 data points with blood glucose concentrations ranging from 680 to 1 100 mg/L. Reproducibility was measured for healthy fasting volunteers. The results show that the means of BGL detected by NBGMA and ANA are very close to each other, and the difference of standard deviation (SD) is 24.7 mg/L. The correlative coefficient is 0.807. The coefficient of variation (CV) is 4% at 921.6 mg/L. The resultant regression is evaluated by the Clarke error grid analysis (EGA) and all data points are included in the clinically acceptable regions (region A: 100%, region B: 0%). Accordingly, it is feasible to measure BGL with COEM.
引用
收藏
页码:982 / 986
页数:4
相关论文
共 61 条
[1]  
Chen Z.-c.(2008)A primary research of non-invasive glucose measuring apparatus[J] Chinese Journal of Sensors and Actuators 21 1119-1123
[2]  
Jin X.-l.(2004)Non-invasive monitoring of gingival crevicular fluid for estimation of blood glucose level[J] Medical and Biological Engineering, and Computing 43 322-327
[3]  
Xu X.-w.(2005)Technology and prospects of noninvasive blood glucose measurement[J] Journal of Biomedical Engineering 22 171-174
[4]  
Zhu J.-m.(2005)Frequency and perceived burden of diabetes self-management activities in employees with insulin-treated diabetes: Relationships with health outcomes[J] Diabetes Res Clin Pract 68 56-64
[5]  
Wang D.-ya.(2008)A novel disposable amperometric UA strip[J] Sensors and Actuators, B: Chemical 129 710-715
[6]  
Yamaguchi M.(2006)Biological effect of far-infrared therapy on increasing skin microcirculation in rats[J] Photodermatology, Photoimmunology & Photomedicine 22 78-86
[7]  
Kawabata Y.(2007)Noninvasive continuous glucose monitoring using photoacoustic technology-results from the first 62 subjects[J] Diabetes Technol Ther 9 68-74
[8]  
Kambe S.(2007)Development and clinical application of biosensor for detecting uric acid in whole-blood[J] Chinese Journal of Analytical Chemistry 35 615-618
[9]  
Wardell K.(2005)Noninvasive and minimally invasive methods for transdermal glucose monitoring[J] Diabetes Technol Ther 7 174-197
[10]  
Mystrom F. H.(2005)Error grid analysis of noninvasive glucose monitoring via gingival crevicular fluid[J] IEEE Trans Biomed Eng 52 1796-1798