Quantification of femtomolar concentrations of the CYP3A substrate midazolam and its main metabolite 1′-hydroxymidazolam in human plasma using ultra performance liquid chromatography coupled to tandem mass spectrometry

被引:0
作者
Jürgen Burhenne
Birte Halama
Monika Maurer
Klaus-Dieter Riedel
Nicolas Hohmann
Gerd Mikus
Walter E. Haefeli
机构
[1] University of Heidelberg,Department of Clinical Pharmacology and Pharmacoepidemiology
来源
Analytical and Bioanalytical Chemistry | 2012年 / 402卷
关键词
Midazolam; 1′-hydroxymidazolam; UHPLC; Mass spectrometry; CYP3A;
D O I
暂无
中图分类号
学科分类号
摘要
The benzodiazepine midazolam is a probe drug used to phenotype cytochrome P450 3A activity. In this situation, effective sedative concentrations are neither needed nor desired, and in fact the use of very low doses is advantageous. We therefore developed and validated an assay for the femtomolar quantification of midazolam and 1′-hydroxymidazolam in human plasma. Plasma (0.25 mL) and 96-well-based solid-phase extraction were used for sample preparation. Extraction recoveries ranged between 75 and 92% for both analytes. Extracts were chromatographed within 2 min on a Waters BEH C18 1.7 μm UPLC® column with a fast gradient consisting of formic acid, ammonia, and acetonitrile. Midazolam and 1′-hydroxymidazolam were quantified using deuterium- and 13C-labeled internal standards and positive electrospray tandem mass spectrometry in the multiple reaction monitoring mode, which yielded lower limits of quantification of 50 fg/mL (154 fmol/L) and 250 fg/mL (733 fmol/L) and a corresponding precision of <20%. The calibrated concentration ranges were linear for midazolam (0.05–250 pg/mL) and 1′-hydroxymidazolam (0.25–125 pg/mL), with correlation coefficients of >0.99. Within-batch and batch-to-batch precision in the calibrated ranges for both analytes were <14% and <12%. No ion suppression was detectable, and plasma matrix effects were minimized to <15% (<25%) for midazolam (1′-hydroxymidazolam). The assay was successfully applied to assess the kinetics of midazolam in two human volunteers after the administration of single oral microgram doses (1–100 μg). This ultrasensitive assay allowed us to quantify the kinetics of midazolam and 1′-hydroxymidazolam for at least 10 h, even after the administration of only 1 μg of midazolam.
引用
收藏
页码:2439 / 2450
页数:11
相关论文
共 50 条
  • [31] Quantification of clomiphene metabolite isomers in human plasma by rapid-resolution liquid chromatography–electrospray ionization–tandem mass spectrometry
    Boian Ganchev
    Georg Heinkele
    Reinhold Kerb
    Matthias Schwab
    Thomas E. Mürdter
    Analytical and Bioanalytical Chemistry, 2011, 400 : 3429 - 3441
  • [32] Simultaneous determination of novel ketolide antibiotic nafithromycin and its major metabolite in human plasma using liquid chromatography tandem mass spectrometry
    Patil, Kiran R.
    Yeole, Ravindra D.
    de Zwart, Marcel
    Pruim, Peter
    BIOANALYSIS, 2019, 11 (19) : 1767 - 1776
  • [33] Development and validation of a method using supported liquid extraction for the simultaneous determination of midazolam and 1′-hydroxy-midazolam in human plasma by liquid chromatography with tandem mass spectrometry detection
    Svanstrom, Camilla
    Hansson, Gunnar P.
    Svensson, Leif D.
    Sennbro, Carl Johan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 58 : 71 - 77
  • [34] Gabapentin quantification in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Application to bioequivalence study
    Ifa, DR
    Falci, M
    Moraes, ME
    Bezerra, FAF
    Moraes, MO
    de Nucci, G
    JOURNAL OF MASS SPECTROMETRY, 2001, 36 (02): : 188 - 194
  • [35] A semi-automated 96-well plate method for the simultaneous determination of oral contraceptives concentrations in human plasma using ultra performance liquid chromatography coupled with tandem mass spectrometry
    Licea-Perez, Hermes
    Wang, Sherry
    Bowen, Chester L.
    Yang, Eric
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 69 - 76
  • [36] Simple and rapid determination of norethindrone in human plasma by supported liquid extraction and ultra performance liquid chromatography with tandem mass spectrometry
    Gong, Zhilong
    Chandler, Kiresha
    Webster, Stephen
    Kerley, Remy
    Buist, Susan
    McCort-Tipton, Melanie
    TALANTA, 2012, 91 : 77 - 82
  • [37] Flow injection analysis vs. ultra high performance liquid chromatography coupled with tandem mass spectrometry for determination of imatinib in human plasma
    Micova, Katerina
    Friedecky, David
    Faber, Edgar
    Polynkova, Adriana
    Adam, Tomas
    CLINICA CHIMICA ACTA, 2010, 411 (23-24) : 1957 - 1962
  • [38] Simple and sensitive assay for quantification of oseltamivir and its active metabolite oseltamivir carboxylate in human plasma using high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry: Improved applicability to pharmacokinetic study
    Hu, Zhe-Yi
    Laizure, S. Casey
    Meibohm, Bernd
    Herring, Vanessa L.
    Parker, Robert B.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 72 : 245 - 250
  • [39] Determination of acyclovir and its metabolite 9-carboxymethoxymethylguanide in human serum by ultra-high-performance liquid chromatography-tandem mass spectrometry
    Urinovska, Romana
    Kacirova, Ivana
    Sagan, Jiri
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (16) : 3080 - 3088
  • [40] Quantitative analysis of anandamide and related acylethanolamides in human seminal plasma by ultra performance liquid chromatography tandem mass spectrometry
    Amoako, Akwasi A.
    Marczylo, Timothy H.
    Lam, Patricia M. W.
    Willets, Jonathon M.
    Derry, Amanda
    Elson, Janine
    Konje, Justin C.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (31): : 3231 - 3237