A Glass/PDMS Hybrid Microfluidic Chip Embedded with Integrated Electrodes for Contactless Conductivity Detection

被引:1
|
作者
Ou-Lian Li
Yan-Li Tong
Zuan-Guang Chen
Cui Liu
Shen Zhao
Jin-Yuan Mo
机构
[1] Sun Yat-sen University,School of Pharmaceutical Sciences
[2] Sun Yat-sen University,School of Chemistry and Chemical Engineering
来源
Chromatographia | 2008年 / 68卷
关键词
Contactless conductivity detection; Glass/PDMS; Hybrid microchips;
D O I
暂无
中图分类号
学科分类号
摘要
A new glass/PDMS hybrid chip for contactless conductivity detection is reported. This chip consists of a glass substrate with microchannels and a PDMS cover sheet embedded with a small integrated electrode plate. In the region of detection, electrodes are insulated from the microchannel by a formed PDMS membrane about 100 μm in thickness. Without any modification, this glass/PDMS chip is suitable for contactless conductivity detection with good properties, such as excellent heat-dissipation, stable electroosmotic flow, high separation efficiency, satisfactory sensitivity, simple construction and high degree of integration. Its feasibility and performance had been demonstrated by analyzing inorganic ions and amino acids in mixtures, and alkaloids in traditional Chinese medicine. The limits of detection reached micromole per liter (μmol L−1) levels. This microchip could be promising for mass production due to its stability, reproducibility, ease of fabrication and low cost.
引用
收藏
页码:1039 / 1044
页数:5
相关论文
共 19 条
  • [1] A Glass/PDMS Hybrid Microfluidic Chip Embedded with Integrated Electrodes for Contactless Conductivity Detection
    Li, Ou-an
    Tong, Yan-Li
    Chen, Zuan-Guang
    Liu, Cui
    Zhao, Shen
    Mo, Jin-Yuan
    CHROMATOGRAPHIA, 2008, 68 (11-12) : 1039 - 1044
  • [2] Dual fluorescence/contactless conductivity detection for microfluidic chip
    Liu, Cui
    Mo, Yun-yan
    Chen, Zuan-guang
    Li, Xiang
    Li, Ou-lian
    Zhou, Xie
    ANALYTICA CHIMICA ACTA, 2008, 621 (02) : 171 - 177
  • [3] A glass/PDMS electrophoresis microchip embedded with molecular imprinting SPE monolith for contactless conductivity detection
    Zhai, Haiyun
    Li, Jiangmei
    Chen, Zuanguang
    Su, Zihao
    Liu, Zhenping
    Yu, Xiao
    MICROCHEMICAL JOURNAL, 2014, 114 : 223 - 228
  • [4] DETERMINATION OF OFLOXACIN IN OFLOXACIN EAR DROPS BY MICROFLUIDIC CHIP WITH CONTACTLESS CONDUCTIVITY DETECTION
    Chen, Bing
    Mai, Qihong
    Chen, Qiumei
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (11) : 1513 - 1523
  • [5] A thin cover glass chip for contactless conductivity detection in microchip capillary electrophoresis
    Chen, Zuanguang
    Li, Quanwen
    Li, Oulian
    Zhou, Xie
    Lan, You
    Wei, Yuanfang
    Mo, Jinyuan
    TALANTA, 2007, 71 (05) : 1944 - 1950
  • [6] A microchip electrophoresis system with integrated in-plane electrodes for contactless conductivity detection
    Lichtenberg, J
    de Rooij, NF
    Verpoorte, E
    ELECTROPHORESIS, 2002, 23 (21) : 3769 - 3780
  • [7] Determination of hydrazines by chip electrophoresis with contactless conductivity detection
    Kumar, Ashwini
    Burns, Jacob
    Hoffmann, Werner
    Demattio, Horst
    Malik, Ashok Kumar
    Matysik, Frank-Michael
    ELECTROPHORESIS, 2011, 32 (08) : 920 - 925
  • [8] Glass/PDMS hybrid microfluidic device integrating vertically aligned SWCNTs to ultrasensitive electrochemical determinations
    Moraes, Fernando Cruz
    Lima, Renato Sousa
    Segato, Thiago Pinotti
    Cesarino, Ivana
    Cetino, Jhanisus Leonel Melendez
    Spinola Machado, Sergio Antonio
    Gomez, Frank
    Carrilho, Emanuel
    LAB ON A CHIP, 2012, 12 (11) : 1959 - 1962
  • [9] A novel microchip based on indium tin oxide coated glass for contactless conductivity detection
    Zhao, Jing
    Chen, Zuanguang
    Li, Xinchun
    Pan, Jianbin
    TALANTA, 2011, 85 (05) : 2614 - 2619
  • [10] Enantiomeric separation of underivatized small amines in conventional and on-chip capillary electrophoresis with contactless conductivity detection
    Gong, Xiao Yang
    Hauser, Peter C.
    ELECTROPHORESIS, 2006, 27 (21) : 4375 - 4382