Reliability testing and reliability analysis of the over-load protective relay

被引:0
作者
Jing-ying Zhao
Hong-jian Chen
Guo-jin Liu
Yong Zhang
Pin-hua Wu
机构
[1] Delixi Group Co.,Postdoctoral Research Work Station
[2] Ltd,Electrical Apparatus Institute
[3] Heibei University of Technology,undefined
来源
Journal of Zhejiang University-SCIENCE A | 2007年 / 8卷
关键词
Over-load protective relay; Protective success ratio; Sampling and checking plan; Reliability testing; Reliability analysis; TB114.3; O224; O211.6;
D O I
暂无
中图分类号
学科分类号
摘要
The over-load protective relay is widely used for motor protection. The reliability of the over-load protective relay directly affects the safe running of a motor. The reliability testing and reliability analysis of the over-load protective relay is an important way to improve the reliability of products. In this paper, the reliability test method of the over-load protective relay is studied, and the reliability tests of the typical products are carried out on a reliability tester developed by authors. In terms of the testing results, the reliability analysis is finished. The failure reasons are found and the measures are put forward to improve the reliability of the products.
引用
收藏
页码:475 / 480
页数:5
相关论文
共 5 条
[1]  
Wu C.P.(2005)Silver based eelctric contact material Yunnan Metal Lurgy 34 46-51
[2]  
Chen J.C.(undefined)undefined undefined undefined undefined-undefined
[3]  
Zhou X.L.(undefined)undefined undefined undefined undefined-undefined
[4]  
Li Y.H.(undefined)undefined undefined undefined undefined-undefined
[5]  
Xian C.Q.(undefined)undefined undefined undefined undefined-undefined