Quantitative assessment of right ventricular systolic function by the analysis of right ventricular contrast time-intensity curve

被引:0
作者
Wang Lin
Deng Youbin
Li Tianliang
Yang Haoyi
机构
[1] Huazhong University of Science and Technology,Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College
关键词
time-intensity curve; curve fitting; right ventricular contrast; right ventricular systolic function;
D O I
10.1007/BF02911370
中图分类号
学科分类号
摘要
To study reliability and reliable indices of quantitative assessment of right ventricular systolic function by time-intensity curve (TIC) with right ventricular contrast, 5% sonicated human albumin was injected intravenously at a does of 0.08 ml/kg into 10 dogs at baseline status and cardiac insufficiency. Apical four-chamber view was observed for washin and washout of contrast agent from right ventricle. The parameters of TIC were obtained by curve fitting. The differences of parameters were analyzed in different states of cardiac functions. Among the parameters derived from TIC, the time constant (k) was decreased significantly with decline of cardiac function (P<0.001). But half-time of decent of peak intensity (HT) and mean-transit-time (MTT) of washout were increased significantly (P<0.001). The k was strongly related to cardiac output of right ventricle (CO) and ejection fraction (EF) of left ventricle and fractional shortening (FS) of left ventricle. Right ventricular systolic function could be assessed reliably by the parameters derived from TIC with right ventricular contrast echocardiography. The k, HT and MTT are reliable indices for quantitative assessment of right ventricular systolic function.
引用
收藏
页码:607 / 609
页数:2
相关论文
共 17 条
  • [1] Spencer K T(1999)Assessment of right ventricular systolic and diastolic performance using automated border detection Echocardiography 16 643-643
  • [2] Garcia M J(1993)Ultrasonic backscatter system for automated online endocardial boundary detection J Am Coll Cardiol 22 839-839
  • [3] Weinart L(1988)Determination of ejection fraction from contrast echocardiography using videodensitometry in an in vitro model J Ultrasound Med 7 581-581
  • [4] Mareds R H(1998)Myocardial perfusion characteristic and hemodynamic profile of MRX 115, a venous echocardiographic contrast agent, during acute myocardial infarction J Am Soc Echocardiogr 11 36-36
  • [5] Bednrz J(1991)Quantification of myocardial perfusion with contrast echocardiography Am J Cardiac Imag 5 200-200
  • [6] Coulden R(1996)Analysis of regional cerebral blood flow in dogs, with an experimental microbubble based US contrast agent Radiology 201 119-119
  • [7] Xie F(1997)Colltrast ultrasonography for 2-D opacification of heart cavities, peripheral vessels, kiney and muscle Ultrasound in Med & Bio 23 975-975
  • [8] Meltzer R S(undefined)undefined undefined undefined undefined-undefined
  • [9] Jonathan R L(undefined)undefined undefined undefined undefined-undefined
  • [10] Christion F(undefined)undefined undefined undefined undefined-undefined