A novel compression garment with adhesive silicone stripes improves repeated sprint performance - a multi-experimental approach on the underlying mechanisms

被引:31
作者
Born D.-P. [1 ,3 ]
Holmberg H.-C. [2 ]
Goernert F. [1 ]
Sperlich B. [1 ,3 ]
机构
[1] Department of Sport Science, University of Wuppertal, Fuhlrottstraße 10, Wuppertal
[2] Swedish Winter Sports Research Centre, Department of Health Sciences, Mid Sweden University, östersund
[3] Department of Sport Sciences, Integrative and Experimental Exercise Science, University of Würzburg, Würzburg
关键词
Blood flow; Clothing; Oscillation; Oxygen uptake; Oxygenation; Textile; Tissue saturation index; Venous system; Video analysis;
D O I
10.1186/2052-1847-6-21
中图分类号
学科分类号
摘要
Background: Repeated sprint performance is determined by explosive production of power, as well as rapid recovery between successive sprints, and there is evidence that compression garments and sports taping can improve both of these factors. Methods: In each of two sub-studies, female athletes performed two sets of 30 30-m sprints (one sprint per minute), one set wearing compression garment with adhesive silicone stripes (CGSS) intended to mimic taping and the other with normal clothing, in randomized order. Sub-study 1 (n = 12) focused on cardio-respiratory, metabolic, hemodynamic and perceptual responses, while neuronal and biomechanical parameters were examined in sub-study 2 (n = 12). Results: In both sub-studies the CGSS improved repeated sprint performance during the final 10 sprints (best P < 0.01, d = 0.61). None of the cardio-respiratory or metabolic variables monitored were altered by wearing this garment (best P = 0.06, d = 0.71). Also during the final 10 sprints, rating of perceived exertion by the upper leg muscles was reduced (P = 0.01, d = 1.1), step length increased (P = 0.01, d = 0.91) and activation of the m. rectus femoris elevated (P = 0.01, d = 1.24), while the hip flexion angle was lowered throughout the protocol (best P < 0.01, d = 2.28) and step frequency (best P = 0.34, d = 0.2) remained unaltered. Conclusion: Although the physiological parameters monitored were unchanged, the CGSS appears to improve performance during 30 30-m repeated sprints by reducing perceived exertion and altering running technique. © 2014 Born et al.; licensee BioMed Central Ltd.
引用
收藏
相关论文
共 78 条
[21]  
Kase K., Wallis J., Kase T., Clinical Therapeutic Application of the Kinesio Taping Method, (2003)
[22]  
Partsch H., Clark M., Bassez S., Benigni J.P., Becker F., Blazek V., Caprini J., Cornu-Thenard A., Hafner J., Flour M., Measurement of lower leg compression in vivo: recommendations for the performance of measurements of interface pressure and stiffness: consensus statement, Dermatol Surg, 32, pp. 224-232, (2006)
[23]  
Gaied I., Drapier S., Lun B., Experimental assessment and analytical 2D predictions of the stocking pressures induced on a model leg by Medical Compressive Stockings, J Biomech, 39, pp. 3017-3025, (2006)
[24]  
Sperlich B., Born D.P., Kaskinoro K., Kalliokoski K.K., Laaksonen M.S., Squeezing the muscle: compression clothing and muscle metabolism during recovery from high intensity exercise, PLoS One, 8, (2013)
[25]  
Kennedy M.D., Haykowsky M.J., Boliek C.A., Esch B.T., Scott J.M., Warburton D.E., Regional muscle oxygenation differences in vastus lateralis during different modes of incremental exercise, Dyn Med, 5, (2006)
[26]  
Chance B., Nioka S., Kent J., McCully K., Fountain M., Greenfeld R., Holtom G., Time-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscle, Anal Biochem, 174, pp. 698-707, (1988)
[27]  
Borg G., Perceived exertion as an indicator of somatic stress, Scand J Rehabil Med, 2, pp. 92-98, (1970)
[28]  
Doan B.K., Kwon Y.H., Newton R.U., Shim J., Popper E.M., Rogers R.A., Bolt L.R., Robertson M., Kraemer W.J., Evaluation of a lower-body compression garment, J Sports Sci, 21, pp. 601-610, (2003)
[29]  
Salo A.I., Bezodis I.N., Batterham A.M., Kerwin D.G., Elite sprinting: are athletes individually step-frequency or step-length reliant?, Med Sci Sports Exerc, 43, pp. 1055-1062, (2011)
[30]  
Hermens H.J., European Recommendations for Surface Electromyography: Results of the SENIAM project, (1999)