A nonparametric method for intensity inhomogeneity correction in MRI brain images by fusion of Gaussian surfaces

被引:0
|
作者
Sudip Kumar Adhikari
Jamuna Kanta Sing
Dipak Kumar Basu
Mita Nasipuri
Punam Kumar Saha
机构
[1] Neotia Institute of Technology,Department of Computer Science and Engineering
[2] Management and Science,Department of Computer Science and Engineering
[3] Jadavpur University,Department of Electrical and Computer Engineering
[4] University of Iowa,undefined
来源
关键词
Magnetic resonance imaging (MRI); Segmentation; Intensity inhomogeneity; Intensity nonuniformity; Bias field correction;
D O I
暂无
中图分类号
学科分类号
摘要
Intensity inhomogeneity (IIH) or bias field in magnetic resonance imaging (MRI) severely affects quantitative image analysis. This paper presents a nonparametric IIH-correction strategy in MRI brain images by fusing multiple Gaussian surfaces. The IIH is modeled as a slowly varying multiplicative noise along with the actual tissue signals. The method does not require a priori knowledge on the intensity probability distribution; rather, it works directly on spatial domains using local image gradients. The method has four steps. Firstly, it extracts different potential tissue regions by considering image histogram. Secondly, an approximated bias field is estimated by fitting a Gaussian surface on the gradient map of each of the homogeneous tissue regions by considering its center as the center of mass. The intensity inhomogeneity field of the entire image is then obtained by fusion of these bias fields. Finally, this IIH field is iteratively removed from the image to obtain the IIH-corrected image. The proposed method is evaluated extensively on popular BrainWeb simulated MRI brain databases and also on some real-patient MRI brain images. Both qualitative and quantitative evaluations of the proposed method reveal its efficiency in removing the bias field in MRI brain images. The standard deviation, coefficient of variation of different tissue regions and coefficient of joint variation between gray matter and white matter are significantly reduced in greater proportion as compared to other standard methods in the case of T2-weighted MRI and come very closer to the ground truths.
引用
收藏
页码:1945 / 1954
页数:9
相关论文
共 50 条
  • [1] A nonparametric method for intensity inhomogeneity correction in MRI brain images by fusion of Gaussian surfaces
    Adhikari, Sudip Kumar
    Sing, Jamuna Kanta
    Basu, Dipak Kumar
    Nasipuri, Mita
    Saha, Punam Kumar
    SIGNAL IMAGE AND VIDEO PROCESSING, 2015, 9 (08) : 1945 - 1954
  • [2] A nonparametric MRI inhomogeneity correction method
    Manjon, Jose V.
    Lull, Juan J.
    Carbonell-Caballero, Jose
    Garcia-Marti, Gracian
    Marti-Bonmati, Luis
    Robles, Montserrat
    MEDICAL IMAGE ANALYSIS, 2007, 11 (04) : 336 - 345
  • [3] Intensity inhomogeneity correction of MRI images using InhomoNet
    Venkatesh, Vishal
    Sharma, Neeraj
    Singh, Munendra
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2020, 84
  • [4] Correction for Intensity Inhomogeneity in MRI
    Hui, C.
    Narayana, P.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [5] Enhanced Homomorphic Unsharp Masking method for intensity inhomogeneity correction in brain MR images
    Blessy, Praylin Selva S. A.
    Sulochana, Helen C.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2020, 8 (01): : 40 - 48
  • [6] Intensity Inhomogeneity Correction in Clinical Pediatric Spinal Cord MRI Images
    Alizadeh, Mahdi
    Mohamed, Feroze B.
    Faro, Scott H.
    Shah, Pallav
    Conklin, Chris J.
    Middleton, Devon M.
    Saksena, Sona
    Shahrampour, Shiva
    Mulcahey, M. J.
    2015 41ST ANNUAL NORTHEAST BIOMEDICAL ENGINEERING CONFERENCE (NEBEC), 2015,
  • [7] A nonparametric method for automatic correction of intensity nonuniformity in MRI data
    Sled, JG
    Zijdenbos, AP
    Evans, AC
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (01) : 87 - 97
  • [8] Intensity inhomogeneity correction for surface-coil MR images by image fusion
    Lai, SH
    Fang, M
    FUSION'98: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MULTISOURCE-MULTISENSOR INFORMATION FUSION, VOLS 1 AND 2, 1998, : 880 - 887
  • [9] An intensity standardization-based method for image inhomogeneity correction in MRI
    Zhuge, Ying
    Udupa, Jayaram K.
    Liu, Jiamin
    Saha, Punam K.
    MEDICAL IMAGING 2006: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES PTS 1 AND 2, 2006, 6143
  • [10] A review of methods for correction of intensity inhomogeneity in MRI
    Vovk, Uros
    Pernus, Franjo
    Likar, Bostjan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (03) : 405 - 421