Study on the Influence of Frangible Roof Performance of Tank Explosion Under Multi-field Coupling

被引:0
作者
Yuqi Ding
Ye Lu
Zengtao Chen
机构
[1] Northeast Petroleum University,College of Mechanical Science and Engineering
[2] University of Alberta,Department of Mechanical Engineering
来源
Journal of Failure Analysis and Prevention | 2019年 / 19卷
关键词
Storage tank; Explosion load; Multi-field coupling; Structural response; Frangible roof;
D O I
暂无
中图分类号
学科分类号
摘要
Taking the 3000-m3 vertical vault storage tank as the research object, the finite element calculation method is used to calculate the pressure and temperature of the fluid during the explosion of the tank. By calculating the structural response of storage tank using multi-field coupling method, the distribution of stress and the deformation of tank are obtained. The tank frangible roof performance influenced by explosion load in different working conditions is analyzed. The results show that the failure pressures of the tank roof are the same in empty-tank, half-tank and full-tank conditions, and the damage pressure of the tank shell and bottom gradually increases with the storage liquid level. Temperature also affects the failure pressure at different locations. At the same location, the higher the temperature, the lower the failure pressure. When the tank is empty, the failure times of the roof and the bottom are almost the same, the failure time of tank shell is obviously earlier than that of other locations. The intensity ratio k is less than 1.5, which means the tank does not have frangible roof performance. For the liquid level of half tank and full tank, no matter where the explosion point is, the failure pressure at the roof-to-shell location is smaller than other locations, and the failure time at the roof-to-shell location is obviously earlier than other locations. The intensity ratio k is bigger than 2.5, which means the tank have frangible roof performance.
引用
收藏
页码:1455 / 1463
页数:8
相关论文
共 56 条
[1]  
Noret E(2012)Safety of atmospheric storage tanks during accidental explosions Eur. J. Environ. Civ. Eng. 16 998-1022
[2]  
Prod’homme G(2014)储罐区火灾爆炸引发多米诺效应的风险分析 (Risk analysis of Domino effect caused by fire and explosion in tank area) Fire Sci. Technol. 33 1453-1456
[3]  
Yalamas T(2015)锥顶钢储罐内部可燃气体爆炸冲击荷载的CFD模拟 (CFD simulation of internal flammable gas explosion loading in cone-roof steel tanks) J. Vib. Shock. 34 150-156
[4]  
Zhao CY(2016)Numerical simulation of internal gaseous explosion loading in large-scale cylindrical tanks with fixed roof Thin-Walled Struct. 105 16-28
[5]  
Hu K(2011)可燃气体爆炸对刚壁冲击特性的实验研究 (Experimental research on the characteristic of impact caused by a blast of inflammable mixture to a rigid wall) J. Harbin Eng. Univ. 32 1001-1006
[6]  
Zhao Y(2011)爆炸作用下薄壁柱壳结构动力响应实验研究 (Experimental research on dynamic response mechanism of thin cylindrical shell blast loading) J. Nanjing Univ. Sci. Technol. 35 621-626
[7]  
Wang Z(2010)Temperature and pressure influence on explosion pressures of closed vessel propane-air deflagrations J. Hazard. Mater. 174 548-555
[8]  
Hu K(2010)Detonation-driven fracture in thin shell structures: numerical studies Combust. Explos. Shock Waves 46 103-110
[9]  
Zhao Y(2018)Effect of shell material on the detonation of an explosive charge Combust. Explos. Shock Waves 54 502-510
[10]  
Lu SZ(2011)Explosion resistance of a steel cylindrical shell Combust. Explos. Shock Waves 47 115-122