Heat flux distribution on circulating fluidized bed boiler water wall

被引:2
作者
Lu J. [1 ]
Yu L. [2 ]
Yue G. [1 ]
Yang H. [1 ]
Zhang J. [1 ]
Zhang M. [2 ]
Yang Z. [2 ]
机构
[1] Department of Thermal Engineering, Tsinghua University
[2] Harbin Boiler Works Co. Ltd.
来源
Frontiers of Energy and Power Engineering in China | 2008年 / 2卷 / 2期
关键词
CFB boiler; FEA; Heat flux distribution; Supercritical; Water wall;
D O I
10.1007/s11708-008-0027-0
中图分类号
学科分类号
摘要
The future of circulating fluidized bed (CFB) combustion technology is in raising the steam parameters to supercritical levels. Understanding the heat flux distribution on the water wall is one of the most important issues in the design and operation of supercritical pressure CFB boilers. In the present paper, the finite element analysis (FEA) method is adopted to predict the heat transfer coefficient as well as the heat flux of the membrane wall and the results are validated by direct measurement of the temperature around the tube. Studies on the horizontal heat flux distribution were conducted in three CFB boilers with different furnace size, tube dimension and water temperature. The results are useful in supercritical pressure CFB boiler design. © 2008 Higher Education Press and Springer-Verlag GmbH.
引用
收藏
页码:134 / 139
页数:5
相关论文
共 18 条
[1]  
Xin J., Lu J., Yue G., Discussion on developing supercritical pressure circulating fluidized bed boiler, Journal of Engineering for Thermal Energy and Power, 17, pp. 439-441, (2002)
[2]  
Skowyra R.S., Czarnecki T.S., Sun C.Y., Rubow L.N., Design of a Supercritical sliding pressure circulating bed boiler with vertical water walls, Proceedings of the 13th International Conference on Fluidized Bed Combustion, pp. 17-25, (1995)
[3]  
Yu L., Lu J., Wang Z., The future investigation of circulating fluidized bed combustion technology, Journal of Engineering for Thermal Energy and Power, 19, pp. 336-341, (2004)
[4]  
Rajaram S., Next generation CFBC, Chemical Engineering Science, 54, pp. 5565-5571, (1995)
[5]  
Basu P., Halder P.K., A new concept for operation of a pulverized coal fired boiler using circulating fluidized bed firing, Journal of Engineering for Gas Turbines and Power, Transactions of the ASME, 111, pp. 626-630, (1989)
[6]  
Lu J., Zhang J., Yue G., Heat transfer coefficient calculation method of the heater in the circulating fluidized bed furnace, Heat Transfer_Asia Research, 31, pp. 540-550, (2002)
[7]  
Animesh D., Prabir B., An experimental investigation into the heat transfer on wing walls in a circulating fluidized bed boiler, International Journal of Heat and Mass Transfer, 45, pp. 4479-4491, (2002)
[8]  
Andersson B.A., Leckner B., Experimental methods of estimating heat transfer in fluidized bed boilers, International Journal of Heat Mass Transfer, 35, pp. 3353-3362, (1992)
[9]  
Bowen B.D., Fourier M., Grace J.R., Heat transfer in membrane waterwalls, International Journal of Heat Mass Transfer, 34, pp. 1043-1057, (1991)
[10]  
Fang Z., Xie D., Dial N., A new method for solving the inverse conduction problem in steady heat flux measurement, International Journal of Heat Mass Transfer, 40, pp. 3947-3953, (1997)