Use of dual-energy computed tomography to measure skeletal-wide marrow composition and cancellous bone mineral density

被引:0
|
作者
Luke Arentsen
Karen E. Hansen
Masashi Yagi
Yutaka Takahashi
Ryan Shanley
Angela McArthur
Patrick Bolan
Taiki Magome
Douglas Yee
Jerry Froelich
Susanta K. Hui
机构
[1] University of Minnesota,Department of Radiation Oncology
[2] University of Wisconsin School of Medicine and Public Health,Department of Medicine, Division of Rheumatology
[3] Osaka University,Masonic Cancer Center
[4] University of Minnesota,Anatomy Bequest Program
[5] University of Minnesota,Department of Medicine
[6] Center for Magnetic Resonance Research,Department of Radiology
[7] University of Minnesota,Department of Radiation Oncology
[8] University of Minnesota,undefined
[9] Beckman Research Institute,undefined
[10] City of Hope,undefined
来源
Journal of Bone and Mineral Metabolism | 2017年 / 35卷
关键词
Whole-body imaging; Marrow-corrected bone mineral density; Dual-energy CT;
D O I
暂无
中图分类号
学科分类号
摘要
Temporal and spatial variations in bone marrow adipose tissue (MAT) can be indicative of several pathologies and confound current methods of assessing immediate changes in bone mineral remodeling. We present a novel dual-energy computed tomography (DECT) method to monitor MAT and marrow-corrected volumetric BMD (mcvBMD) throughout the body. Twenty-three cancellous skeletal sites in 20 adult female cadavers aged 40–80 years old were measured using DECT (80 and 140 kVp). vBMD was simultaneous recorded using QCT. MAT was further sampled using MRI. Thirteen lumbar vertebrae were then excised from the MRI-imaged donors and examined by microCT. After MAT correction throughout the skeleton, significant differences (p < 0.05) were found between QCT-derived vBMD and DECT-derived mcvBMD results. McvBMD was highly heterogeneous with a maximum at the posterior skull and minimum in the proximal humerus (574 and 0.7 mg/cc, respectively). BV/TV and BMC have a nearly significant correlation with mcvBMD (r = 0.545, p = 0.057 and r = 0.539, p = 0.061, respectively). MAT assessed by DECT showed a significant correlation with MRI MAT results (r = 0.881, p < 0.0001). Both DECT- and MRI-derived MAT had a significant influence on uncorrected vBMD (r = −0.86 and r = −0.818, p ≤ 0.0001, respectively). Conversely, mcvBMD had no correlation with DECT- or MRI-derived MAT (r = 0.261 and r = 0.067). DECT can be used to assess MAT while simultaneously collecting mcvBMD values at each skeletal site. MAT is heterogeneous throughout the skeleton, highly variable, and should be accounted for in longitudinal mcvBMD studies. McvBMD accurately reflects the calcified tissue in cancellous bone.
引用
收藏
页码:428 / 436
页数:8
相关论文
共 50 条
  • [1] Use of dual-energy computed tomography to measure skeletal-wide marrow composition and cancellous bone mineral density
    Arentsen, Luke
    Hansen, Karen E.
    Yagi, Masashi
    Takahashi, Yutaka
    Shanley, Ryan
    McArthur, Angela
    Bolan, Patrick
    Magome, Taiki
    Yee, Douglas
    Froelich, Jerry
    Hui, Susanta K.
    JOURNAL OF BONE AND MINERAL METABOLISM, 2017, 35 (04) : 428 - 436
  • [2] Traumatic bone marrow lesions in dual-energy computed tomography
    Ren, Qiuping
    Tang, Deqiu
    Xiong, Zhiyuan
    Zhao, Heng
    Zhang, Shuixing
    INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [3] Traumatic bone marrow lesions in dual-energy computed tomography
    Qiuping Ren
    Deqiu Tang
    Zhiyuan Xiong
    Heng Zhao
    Shuixing Zhang
    Insights into Imaging, 13
  • [4] Evaluation of Functional Marrow Irradiation Based on Skeletal Marrow Composition Obtained Using Dual-Energy Computed Tomography
    Magome, Taiki
    Froelich, Jerry
    Takahashi, Yutaka
    Arentsen, Luke
    Holtan, Shernan
    Verneris, Michael R.
    Brown, Keenan
    Haga, Akihiro
    Nakagawa, Keiichi
    Chakrabarty, Jennifer L. Holter
    Giebel, Sebastian
    Wong, Jeffrey
    Dusenbery, Kathryn
    Storme, Guy
    Hui, Susanta K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (03): : 679 - 687
  • [5] The new fast kilovoltage-switching dual-energy computed tomography for measuring bone mineral density
    Wang, Mingyue
    Wu, Yan
    Zhou, Yue
    Dong, Junqiang
    Hou, Ping
    Gao, Jianbo
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (02) : 801 - 811
  • [6] Application of Dual-Energy Spectral Computed Tomography in Bone Mineral Density Measurement: Phantom and Clinical Research
    Wang, Mingyue
    Wu, Yan
    Zhou, Yue
    Dong, Junqiang
    Hu, Shenshen
    Hou, Ping
    Gao, Jianbo
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2022, 15 : 6887 - 6896
  • [7] Dual-Energy Computed Tomography for Fat Quantification in the Liver and Bone Marrow: A Literature Review
    Molwitz, Isabel
    Leiderer, Miriam
    Oezden, Cansu
    Yamamura, Jin
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2020, 192 (12): : 1137 - 1152
  • [8] Virtual unenhanced images derived from dual-energy computed tomography for assessing bone mineral density and detecting osteoporosis
    Tong, Xiaoyu
    Fang, Xin
    Wang, Shigeng
    Fan, Yong
    Wei, Wei
    Xiao, Qingzhu
    Chen, Anliang
    Liu, Yijun
    Liu, Lei
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (10) : 6571 - 6582
  • [9] ACCURACY OF DUAL-ENERGY COMPUTED TOMOGRAPHY FOR THE DETECTION OF BONE MARROW EDEMA IN PATIENTS WITH AXIAL SPONDYLOARTHRITIS
    Carotti, M.
    Salaffi, F.
    Piccinni, P.
    Di Carlo, M.
    Farah, S.
    Benfaremo, D.
    Luchetti, M. M.
    Giovagnoni, A.
    ANNALS OF THE RHEUMATIC DISEASES, 2020, 79 : 493 - 494
  • [10] Use of computed tomography for assessing bone mineral density
    Schreiber, Joseph J.
    Anderson, Paul A.
    Hsu, Wellington K.
    NEUROSURGICAL FOCUS, 2014, 37 (01)