Determination of Low Wear Rates in Metal-On-Metal Hip Joint Replacements Based on Ultra Trace Element Analysis in Simulator Studies

被引:0
作者
J. P. Kretzer
M. Krachler
J. Reinders
E. Jakubowitz
M. Thomsen
C. Heisel
机构
[1] University of Heidelberg,Laboratory of Biomechanics and Implant Research, Department of Orthopaedics
[2] University of Heidelberg,Institute of Earth Sciences
[3] German Red Cross Hospital,undefined
[4] ARCUS Sportklinik,undefined
来源
Tribology Letters | 2010年 / 37卷
关键词
Chemical analytical techniques; Human joints; Replacements; Biotribology; Wear/failure testing devices;
D O I
暂无
中图分类号
学科分类号
摘要
Metal-on-metal joint bearings are being increasingly used for total hip arthroplasty. Previous results from simulator tests to determine wear of metal-on-metal bearings exhibited high fluctuations. Consequently, wear tests had to be performed for a long period of time to achieve stable values. The aim of this study was to establish a method for the precise measurement of wear of metal-on-metal bearings. Wear was determined by analyzing the concentrations of particles and selected elements in the test medium (serum) using high resolution-inductively coupled plasma-mass spectrometry (HR-ICP-MS). The procedure was first validated and compared to gravimetric measurements on two different implant designs and then applied in wear tests on four total hip resurfacing implants. The validation showed a significant reliability of the HR-ICP-MS method (p ≤ 0.02). The final wear test revealed that the HR-ICP-MS method can precisely detect very low wear rates and accurately characterize alterations in wear progression. The duration of simulation can be reduced due to the high detection power and low fluctuation in HR-ICP-MS wear determination analyses. This approach is suitable for test implants with extremely low wear rates.
引用
收藏
页码:23 / 29
页数:6
相关论文
共 100 条
  • [1] Chan FW(1996)Engineering issues and wear performance of metal on metal hip implants Clin. Orthop. Relat. Res. 333 96-107
  • [2] Bobyn JD(2007)Wear reduction of large head metal-on-metal implants in a hip simulation study Trans. Orthop. Res. Soc. 32 1658-160
  • [3] Medley JB(2001)In vitro comparison of the two hard-hard articulations for total hip replacements Proc. Inst. Mech. Eng. H 215 153-111
  • [4] Krygier JJ(2004)Effect of ion implantation on the tribology of metal-on-metal hip prostheses J. Arthroplasty 19 107-24
  • [5] Yue S(1999)The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants Clin. Orthop. Relat. Res. 369 10-157
  • [6] Tanzer M(2001)Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator Biomed. Mater. Eng. 11 143-47
  • [7] Liao YS(2000)A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements Proc. Inst. Mech. Eng. H 214 39-404
  • [8] Rieker C(2005)Discerning alumina ball wear from confounding metal transfer artifact J. Biomed. Mater. Res. B Appl. Biomater. 75 400-1298
  • [9] Konrad R(2001)A novel low wearing differential hardness, ceramic-on-metal hip joint prosthesis J. Biomech. 34 1291-448
  • [10] Schon R(1998)Low wear and friction in alumina/alumina total hip joints: a hip simulator study Acta Orthop. Scand. 69 443-143