Carbon paste electrode modified with Fe3O4 nanoparticles and BMI.PF6 ionic liquid for determination of estrone by square-wave voltammetry

被引:0
作者
Fernanda Moreira
Tatiane de Andrade Maranhão
Almir Spinelli
机构
[1] Universidade Federal de Santa Catarina—UFSC,Grupo de Estudos de Processos Eletroquímicos e Eletroanalíticos, Departamento de Química, Centro de Ciências Físicas e Matemáticas—CFM
[2] Campus Universitário Reitor João David Ferreira Lima,undefined
来源
Journal of Solid State Electrochemistry | 2018年 / 22卷
关键词
Carbon paste electrode; Fe; O; nanoparticles; Ionic liquid; Estrone; Pork meat; Square-wave voltammetry;
D O I
暂无
中图分类号
学科分类号
摘要
A carbon paste electrode (CPE) modified with Fe3O4 nanoparticles (Fe3O4 NP) and the ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate (IL BMI.PF6) was employed for the electroanalytical determination of estrone (E1) by square-wave voltammetry (SWV). At the modified electrode, cyclic voltammograms of E1 in B–R buffer (pH 12.0) showed an adsorption-controlled irreversible oxidation peak at around +0.365 V. The anodic current increased by a factor of five times and the peak potential shifted 65 mV to less positive values compared with the unmodified CPE. Under optimized conditions, the calibration curve obtained showed two linear ranges: from 4.0 to 9.0 μmol L−1 and from 9.0 to 100.0 μmol L−1. The limits of detection (LOD) and quantification (LOQ) attained were 0.47 and 4.0 μmol L−1, respectively. The proposed modified electrode was applied to the determination of E1 in pork meat samples. Data provided by the proposed modified electrode were compared with data obtained by UV–vis spectroscopy. The outstanding performance of the electrochemical device indicates that Fe3O4 NP and the IL BMI.PF6 are promising materials for the preparation of chemically modified electrodes for the determination of E1.
引用
收藏
页码:1303 / 1313
页数:10
相关论文
共 196 条
  • [11] Ensafi AA(2017)O Microchem J 133 22-30
  • [12] Abarghoui MM(2012) nanoparticles/N-doped graphene for electrocatalytic oxidation of J Solid State Electrochem 16 857-867
  • [13] Rezaei B(2015)-cysteine J Electroanal Chem 741 71-79
  • [14] Li Y(2015)Electrooxidation behavior of warfarin in Fe Sens Actuators B: Chem 220 1131-1138
  • [15] Zhai X(2017)O Sens Actuators B: Chem 243 838-846
  • [16] Liu X(2014) nanoparticles modified carbon paste electrode and its determination in real samples Mater Sci Eng C 36 160-167
  • [17] Wang L(2016)An ionic liquid-Fe J Environ Chem Eng 4 4330-4341
  • [18] Liu H(2017)O J Hazard Mater 330 105-115
  • [19] Wang H(2017) nanoparticles-graphite composite electrode used for nonenzymatic electrochemical determination of hydrogen peroxide J Mol Liq 233 391-397
  • [20] Mani V(2012)Self-assembled monolayer of SH-DNA strand on a magnetic bar carbon paste electrode modified with Fe J Solid State Electrochem 16 273-282