Remaining moment capacity of corroded steel beams

被引:0
|
作者
Yasser Sharifi
Reza Rahgozar
机构
[1] University of Kerman,Department of Civil Engineering
关键词
steel beams; corrosion; thickness loss; remaining moment capacity; environmental exposure;
D O I
暂无
中图分类号
学科分类号
摘要
Steel structures are subjected to corrosion due to environmental exposure and inadequate maintenance. As a result, the carrying capacity and hence the level of safety of this structures diminishes with time due to accumulation of corrosion damage (e.g. section loss). For the assessment of the remaining moment capacity of corrosion damaged I-beams, two methods have been proposed in this paper based on the thickness loss data were compiled from four corroded damaged I-beams, namely the simple and accurate assessment methods. These methods give the quantitative relationship between the magnitude of structural defects (loss of thickness) and the corresponding remaining moment capacity (expressed as percentage of the as-new strength) of corrosion damaged beams. These methods require only the information regarding thickness loss of the appropriate elements of the members (flanges and web) and the capacity of the beam in its as-new condition, to assess the remaining moment capacity of a corrosion damaged beam. The thickness loss information can be provided by visual inspection or thickness measurement of a member. These assessment methods will help the practicing engineer to make a fast and reliable decision regarding the remaining moment capacity of corrosion damaged I-beam.
引用
收藏
页码:165 / 176
页数:11
相关论文
共 50 条
  • [31] Analytical assessment of the bearing capacity of RC beams with corroded steel bars beyond concrete cover cracking
    Triantafyllou, Garyfalia G.
    Rousakis, Theodoros C.
    Karabinis, Athanasios I.
    COMPOSITES PART B-ENGINEERING, 2017, 119 : 132 - 140
  • [32] Rehabilitation of Corroded Steel Beams Using BFRP Fabric
    Jayasuriya, Sahan
    Bastani, Amirreza
    Kenno, Sara
    Bolisetti, Tirupati
    Das, Sreekanta
    STRUCTURES, 2018, 15 : 152 - 161
  • [33] Moment capacity for steel and recycled waste plastic ducts in post-tensioned beams
    Khatib, Milad
    Abou Saleh, Zaher
    Baalbaki, Oussama
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [34] Flexural capacity of locally buckled steel I-beams under moment gradient
    Mohebkhah, A. (amoheb@malayeru.ac.ir), 1600, Bentham Science Publishers B.V., P.O. Box 294, Bussum, 1400 AG, Netherlands (07):
  • [35] Moment Capacity and Ductility of Reinforced Concrete Beams Strengthened with Ferrocement Including Steel Bars
    Xiong, Guangjing
    Ye, Surong
    Zhu, Zhanxian
    ADVANCED SCIENCE LETTERS, 2011, 4 (8-10) : 3249 - 3255
  • [36] Bending Moment Capacity of Cold-Formed Steel Built-Up Beams
    Mohamed Ghannam
    International Journal of Steel Structures, 2019, 19 : 660 - 671
  • [37] Moment redistribution capacity of continuous RC beams with High-Strength steel reinforcement
    Luo, Da
    Li, Bing
    STRUCTURES, 2023, 51 : 13 - 24
  • [39] Residual Flexural Capacity of Corroded Prestressed Reinforced Concrete Beams
    Kioumarsi, Mahdi
    Benenato, Armando
    Ferracuti, Barbara
    Imperatore, Stefania
    METALS, 2021, 11 (03) : 1 - 22
  • [40] Ultimate flexural and shear capacity of concrete beams with corroded reinforcement
    Bhargava, Kapilesh
    Ghosh, A. K.
    Mori, Yasuhiro
    Ramanujam, S.
    STRUCTURAL ENGINEERING AND MECHANICS, 2007, 27 (03) : 347 - 363