Sensitive and selective determination of mercury by differential pulse stripping voltammetry after accumulation of mercury vapour on a gold plated graphite electrode

被引:0
|
作者
Mieczysław Korolczuk
机构
[1] Maria Curie Skłodowska University,Faculty of Chemistry
来源
Fresenius' Journal of Analytical Chemistry | 1997年 / 357卷
关键词
Mercury; Differential Pulse; Mercury Vapour; Anal Chim; Anodic Strip Voltammetry;
D O I
暂无
中图分类号
学科分类号
摘要
A selective and sensitive method is proposed for the determination of mercury by anodic stripping voltammetry after its preconcentration from the gas phase. Mercury from the sample solution is reduced to elemental Hg by SnCl2 and volatilized by the bubbles of a carrier gas. The gas containing mercury vapour is dried and passed through a capillary onto a gold coated graphite electrode. An anodic stripping voltam-mogram is recorded from 0.1 mol/1 HClO4 + 3 × 10−3 mol/1 HCl solution. The calibration curve is linear from 1 × 10−9 to 4 × 10−8 mol/1 Hg(NO3)2. The absolute detection limit is 0.46 ng Hg. The relative standard deviations for 4 × 10−9 mol/1 and 2 × 10−8 mol/1 Hg(NO3)2 are 9.8% and 6.1%, respectively n = 5).
引用
收藏
页码:389 / 391
页数:2
相关论文
共 50 条
  • [21] Stripping voltammetric determination of mercury(II) based on SWCNT-PhSH modified gold electrode
    Wei, Jiali
    Yang, Duangguang
    Chen, Hongbiao
    Gao, Yong
    Li, Huaming
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 : 968 - 974
  • [22] ABTS-Multiwalled Carbon Nanotubes Nanocomposite/Bi Film Electrode for Sensitive Determination of Cd and Pb by Differential Pulse Stripping Voltammetry
    Deng, Wenfang
    Tan, Yueming
    Fang, Zhengfa
    Xie, Qingji
    Li, Yunyong
    Liang, Xiaoling
    Yao, Shouzhuo
    ELECTROANALYSIS, 2009, 21 (22) : 2477 - 2485
  • [23] Electrochemical Polishing of the Surface of a Gold Electrode and Its Effect on the Sensitivity of the Stripping Voltammetric Determination of Mercury(II)
    S. S. Ermakov
    A. V. Borzhitskaya
    L. N. Moskvin
    Journal of Analytical Chemistry, 2001, 56 : 542 - 545
  • [24] The convenient determination of palladium at a solid electrode via adsorptive stripping voltammetry at a glassy carbon electrode modified with a random array of mercury nanodroplets
    Abinian, Poobalasingam
    Wildgoose, Gregory G.
    Xiao, Lei
    Compton, Richard G.
    ELECTROANALYSIS, 2008, 20 (14) : 1607 - 1609
  • [25] Anodic stripping voltammetry with gold electrodes as an alternative method for the routine determination of mercury in fish. Comparison with spectroscopic approaches
    Giacomino, Agnese
    Redda, Andrea Ruo
    Squadrone, Stefania
    Rizzi, Marco
    Abete, Maria Cesarina
    La Gioia, Carmela
    Toniolo, Rosanna
    Abollino, Ornella
    Malandrino, Mery
    FOOD CHEMISTRY, 2017, 221 : 737 - 745
  • [26] Strategy for copper speciation in white wine by differential pulse anodic stripping voltammetry, potentiometry with an ion-selective electrode and kinetic photometric determination
    Claudia Wiese
    G. Schwedt
    Fresenius' Journal of Analytical Chemistry, 1997, 358 : 718 - 722
  • [27] COMPARISON OF THE SQUARE-WAVE STRIPPING VOLTAMMETRY OF LEAD AND MERCURY FOLLOWING THEIR ELECTROCHEMICAL OR ABRASIVE DEPOSITION ONTO A PARAFFIN IMPREGNATED GRAPHITE ELECTRODE
    KOMORSKYLOVRIC, S
    LOVRIC, M
    BOND, AM
    ANALYTICA CHIMICA ACTA, 1992, 258 (02) : 299 - 305
  • [28] Differential Pulse Stripping Voltammetry of Mercury(II) Ions at a Cylindrical Carbon-Fiber Microelectrode in the Presence of Au(III) Ions
    G. G. Muntyanu
    Journal of Analytical Chemistry, 2001, 56 : 546 - 551
  • [29] Differential pulse stripping voltammetry of mercury(II) ions at a cylindrical carbon-fiber microelectrode in the presence of Au(III) ions
    Muntyanu, GG
    JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 56 (06) : 546 - 551
  • [30] Determination of selenium(IV) by cathodic stripping voltammetry using a copper-modified mercury-film electrode modified with copper
    N. K. Zaitsev
    E. A. Osipova
    D. M. Fedulov
    E. A. Eremenko
    A. G. Dedov
    Journal of Analytical Chemistry, 2006, 61 : 77 - 83