Sensitive and selective determination of mercury by differential pulse stripping voltammetry after accumulation of mercury vapour on a gold plated graphite electrode

被引:0
|
作者
Mieczysław Korolczuk
机构
[1] Maria Curie Skłodowska University,Faculty of Chemistry
来源
Fresenius' Journal of Analytical Chemistry | 1997年 / 357卷
关键词
Mercury; Differential Pulse; Mercury Vapour; Anal Chim; Anodic Strip Voltammetry;
D O I
暂无
中图分类号
学科分类号
摘要
A selective and sensitive method is proposed for the determination of mercury by anodic stripping voltammetry after its preconcentration from the gas phase. Mercury from the sample solution is reduced to elemental Hg by SnCl2 and volatilized by the bubbles of a carrier gas. The gas containing mercury vapour is dried and passed through a capillary onto a gold coated graphite electrode. An anodic stripping voltam-mogram is recorded from 0.1 mol/1 HClO4 + 3 × 10−3 mol/1 HCl solution. The calibration curve is linear from 1 × 10−9 to 4 × 10−8 mol/1 Hg(NO3)2. The absolute detection limit is 0.46 ng Hg. The relative standard deviations for 4 × 10−9 mol/1 and 2 × 10−8 mol/1 Hg(NO3)2 are 9.8% and 6.1%, respectively n = 5).
引用
收藏
页码:389 / 391
页数:2
相关论文
共 50 条
  • [1] Oligonucleotide Functionalized Microporous Gold Electrode for the Selective and Sensitive Determination of Mercury by Differential Pulse Adsorptive Stripping Voltammetry (DPAdSV)
    Xu Yiwei
    Li Zhihua
    Zhang Wen
    Shi Jiyong
    Zou Xiaobo
    Huang Xiaowei
    Hu Xuetao
    Wang Xin
    ANALYTICAL LETTERS, 2019, 52 (18) : 2938 - 2950
  • [2] Trace determination of mercury by anodic stripping voltammetry at the rotating gold electrode
    Bonfil, Y
    Brand, M
    Kirowa-Eisner, E
    ANALYTICA CHIMICA ACTA, 2000, 424 (01) : 65 - 76
  • [3] Parameters affecting the determination of mercury by anodic stripping voltammetry using a gold electrode
    Giacomino, Agnese
    Abollino, Omella
    Malandrino, Mery
    Mentasti, Edoardo
    TALANTA, 2008, 75 (01) : 266 - 273
  • [4] Determination of Enalapril by Stripping Voltammetry at a Mercury Film Electrode
    A. M. Gusakova
    E. A. Ivanovskaya
    Journal of Analytical Chemistry, 2005, 60 : 436 - 438
  • [5] Simultaneous determination of arsenic and mercury in water at trace levels by differential pulse anodic stripping voltammetry using a simple gold disk electrode
    Dang, Vu Hai
    Yen, Pham Thi Hai
    Phong, Pham Hong
    Duy, Pham Khac
    Ha, Vu Thi Thu
    VIETNAM JOURNAL OF CHEMISTRY, 2019, 57 (03) : 339 - 342
  • [6] Determination of mercury and copper in waste water by anodic-stripping voltammetry at the gold electrode
    Bonfil, Y
    Brand, M
    Kirowa-Eisner, E
    REVIEWS IN ANALYTICAL CHEMISTRY, 2000, 19 (3-4): : 201 - 216
  • [7] Rapid Determination of Mercury in Water by Stripping Voltammetry at a Gold-Modified Carbon Electrode
    L. A. Khustenko
    L. N. Larina
    B. F. Nazarov
    Journal of Analytical Chemistry, 2003, 58 : 262 - 267
  • [8] Rapid determination of mercury in water by stripping voltammetry at a gold-modified carbon electrode
    Khustenko, LA
    Larina, LN
    Nazarov, BF
    JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 58 (03) : 262 - 267
  • [9] Determination of mercury by anodic stripping voltammetry with a gold nanoparticle-modified glassy carbon electrode
    Abollino, Ornella
    Giacomino, Agnese
    Malandrino, Mery
    Piscionieri, Giuseppina
    Mentasti, Edoardo
    ELECTROANALYSIS, 2008, 20 (01) : 75 - 83
  • [10] Trace mercury determination by differential pulse anodic stripping voltammetry using polythiophene-quinoline/glassy carbon modified electrode
    Yoo, KS
    Woo, SB
    Jyoung, JY
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2003, 24 (01) : 27 - 31