Intraoperative verification of parathyroid glands in primary and secondary hyperparathyroidism using near-infrared autofluorescence (IOPA)

被引:0
作者
Henning W. Wolf
Bernhard Grumbeck
Norbert Runkel
机构
[1] Schwarzwald-Baar Klinikum Villingen-Schwenningen,Department of General Surgery
[2] Kantonsspital Aarau AG,Department of Surgery
[3] Klinikum Sankt Elisabeth,undefined
[4] Schwarzwald-Baar Klinikum Villingen-Schwenningen,undefined
[5] Sana-Klinikum Offenbach,undefined
来源
Updates in Surgery | 2019年 / 71卷
关键词
Parathyroid surgery; Hyperparathyroidism; Endocrine surgery; Near-infrared autofluorescence;
D O I
暂无
中图分类号
学科分类号
摘要
Intraoperative verification of parathyroid glands relies on visual identification by the surgeon and, with some time delay, on serum parathormon measurements and frozen section. Fluorescence imaging, however, is an instant on-table method for direct visualization of parathyroid tissue which is known to exhibit increased autofluorescence intensity when exposed to near-infrared light. In this retrospective observational study, we evaluate the clinical use of this method in a series of patients with primary and secondary hyperparathyroidism. A total of 66 adenomatous and hyperplastic parathyroid glands were examined with intraoperative autofluorescence in 39 patients with primary and secondary hyperparathyroidism using a near-infrared system (KARL STORZ GmbH & Co. KG). The specimens were verified by conventional histology. Fifty-seven of 66 histologically proven adenomatous/hyperplastic glands exhibited autofluorescence. The sensitivity of near-infrared autofluorescence was 0.9 in pHPT and 0.83 in sHPT, respectively. The positive predictive value was 0.93 in pHPT and 1.0 in sHPT, respectively. Near-infrared autofluorescence guidance presents an innovative instant surgical imaging tool with sensitivity in detecting adenomatous and hyperplastic parathyroid glands comparable to current intraoperative methods. Due to its elegant and tracer-free design combined with low follow-up costs, this method can be useful for routine use.
引用
收藏
页码:579 / 585
页数:6
相关论文
共 75 条
  • [1] Khatun Y(2015)Role of intraoperative PTH monitoring and surgical approach in primary hyperparathyroidism Ann Med Surg. 4 301-305
  • [2] Walker A(2011)Near-infrared autofluorescence for the detection of parathyroid glands J Biomed Opt 16 067012-380
  • [3] Jimeno J(2016)Cutting edge in thyroid surgery: autofluorescence of parathyroid glands J Am Coll Surg 223 374-681
  • [4] Hubbard JG(1971)Methylene blue for rapid identification of the parathyroids Br Med J 3 680-622
  • [5] Paras C(2004)Rapid intraoperative localization of parathyroid glands utilizing methylene blue infusion Otolaryngol Head Neck Surg 131 616-2222
  • [6] Keller M(2010)Fluorescence-guided minimally invasive parathyroidectomy: clinical experience with a novel intraoperative detection technique for parathyroid glands World J Surg 34 2217-2381
  • [7] White L(2016)Intra-operative indocyanine green angiography of the parathyroid gland World J Surg 40 2378-774
  • [8] Phay J(2016)The utility of indocyanine green near infrared fluorescent imaging in the identification of parathyroid glands during surgery for primary hyperparathyroidism J Surg Oncol 113 771-543
  • [9] Mahadevan-Jansen A(2016)Parathyroid gland angiography with indocyanine green fluorescence to predict parathyroid function after thyroid surgery Br J Surg 103 537-4580
  • [10] Falco J(2014)Label-free intraoperative parathyroid localization with near-infrared autofluorescence imaging J Clin Endocrinol Metab 99 4574-202