Monitoring the plutonium depletion in dissolution residues of a spent fuel solution using a surrogate and plutonium isotope ratio measurements

被引:0
作者
Alexandre Quemet
Emilie Buravand
Brigitte Catanese
Patrick Huot
Vincent Dalier
Alexandre Ruas
机构
[1] Univ Montpellier,CEA, DES, DMRC
[2] International Atomic Energy Agency,Onsite Laboratory Team, Nuclear Material Laboratory, Office of Safeguards Analytical Services, Department of Safeguards
[3] Tokyo Regional Office,undefined
来源
Journal of Radioanalytical and Nuclear Chemistry | 2020年 / 326卷
关键词
Dissolution; Residues; Plutonium; TIMS; Isotope ratio; Depletion kinetics;
D O I
暂无
中图分类号
学科分类号
摘要
This study presents the development of an innovative experiment using a surrogate, for monitoring the depletion kinetics of plutonium dissolution residues in an irradiated fuel dissolution solution containing a high plutonium concentration. The surrogate, a (U,Pu)O2 compound, was synthesized from a plutonium having an isotopic composition different from the dissolution solution. This helps monitoring the plutonium residue depletion by TIMS measurements of the 240Pu/239Pu isotope ratio. Repeatability better than 83 ppm was achieved for the 240Pu/239Pu ratios in each aliquot of the dissolution profiles allowing qualitative and quantitative interpretation of the kinetic evolution that could not be reached by a conventional direct concentration determination.
引用
收藏
页码:255 / 260
页数:5
相关论文
共 56 条
  • [1] Lee C-G(2015)Ultra-trace analysis of plutonium by thermal ionization mass spectrometry with a continuous heating technique without chemical separation Talanta 141 92-96
  • [2] Suzuki D(2015)Direct isotope ratio analysis of individual uranium-plutonium mixed particles with various U/Pu ratios by thermal ionization mass spectrometry Appl Radiat Isot 96 52-56
  • [3] Esaka F(2016)Thermal ionisation mass spectrometry (TIMS) in nuclear science and technology—a review Anal Methods 8 942-957
  • [4] Magara M(2018)Supported liquid membrane based loading technique for thermal ionization mass spectrometry: an application to plutonium isotopic composition and concentration determination J Radioanal Nucl Chem 317 1367-1376
  • [5] Song K(2017)Zr precipitation kinetics in irradiated fuel dissolution solution by TIMS and ICP-MS: a combined study J Radioanal Nucl Chem 431 8-14
  • [6] Suzuki D(2018)Americium isotope analysis by thermal ionization mass spectrometry using the total evaporation method Int J Mass Spectrom 307 277-284
  • [7] Esaka F(2016)Determining the age and history of plutonium using isotope correlations and experimentally determined data on isotopic abundances of plutonium and 241Am J Radioanal Nucl Chem 47 22-33
  • [8] Miyamoto Y(2018)High concentration measurements of U and Pu with nondestructive and standardless K-edge densitometer device X Ray Spectrom 321 997-1004
  • [9] Magara M(2019)Development and comparison of two high accuracy methods for uranium concentration in nuclear fuel: ID-TIMS and K-edge densitometry J Radioanal Nucl Chem 90 81-85
  • [10] Aggarwal SK(2002)Single-column extraction chromatographic separation of U, Pu, Np and Am Radiochim Acta 374 26-32