Wavelet transform-based protection of transmission line incorporating SSSC with energy storage device

被引:0
作者
H. V. Gururaja Rao
Nagesh Prabhu
R. C. Mala
机构
[1] Manipal Institute of Technology,Department of Electrical and Electronics Engineering
[2] NMAM Institute of Technology,Department of Electrical and Electronics Engineering
来源
Electrical Engineering | 2020年 / 102卷
关键词
Line protection; Wavelet transform; SSSC; Energy storage; Fault index;
D O I
暂无
中图分类号
学科分类号
摘要
Series compensation is generally used with long transmission lines to increase power transfer through the line and to enhance system stability. In the case of voltage source converter-based series flexible AC transmission system (FACTS) controller, an energy storage device can be incorporated at the DC bus which further improves control of real and reactive power flow. However, four-quadrant operation of FACTS controllers with energy storage device poses new challenges for the operation, control and protection of power system. Most commonly used protection scheme for long transmission lines, the distance relay, may not be reliable in case of lines compensated with series FACTS controllers. This paper proposes a new wavelet transform-based relay logic for fast and reliable detection, and classification of faults in a hybrid series-compensated long transmission line incorporating a passive series capacitor and static synchronous series compensator with energy storage device (SSSC-ES). The proposed relay logic is also able to accurately estimate the location of fault, and a wavelet transform-based boundary condition is used to discriminate between internal and external faults. It is shown through various simulation case studies that the four-quadrant operation of SSSC and fault resistance have negligible impact on the performance of the wavelet transform-based relay.
引用
收藏
页码:1593 / 1604
页数:11
相关论文
共 40 条
[1]  
Ghorbani A(2017)Active power based distance protection scheme in the presence of series compensators Prot Control Mod Power Syst 2 7-84
[2]  
Ebrahimi SY(2013)Adaptive distance protection of transmission line in presence of SVC Int J Electr Power Energy Syst 53 78-43
[3]  
Ghorbani M(2000)Adaptive relay setting for FACTS IEEE Trans Power Deliv 15 38-131
[4]  
Singh AR(2015)“Adaptive ground distance protection for UPFC compensated transmission lines: a formulation considering the fault resistance effect Int J Electr Power Energy Syst 7 124-850
[5]  
Dambhare SS(2019)Emulated reactance and resistance by a SSSC incorporating energy storage device Int J Electr Comput Eng 9 840-253
[6]  
Dash PK(2017)High-speed protection scheme based on initial current traveling wave for transmission lines employing mathematical morphology IEEE Trans Power Deliv 32 246-388
[7]  
Pradhan AK(2009)Wavelet transform based digital protection for transmission lines Int J Electr Power Energy Syst 31 379-1227
[8]  
Panda G(2013)Robust transmission line fault classification using wavelet multi resolution analysis Comput Electr Eng 39 1219-1003
[9]  
Liew AC(2017)Wavelet-alienation based transmission line protection scheme IET Gener Transm Distrib 11 995-2163
[10]  
Cruz M(2010)Fault detection and classification in EHV transmission line based on wavelet singular entropy IEEE Trans Power Deliv 25 2156-94