Assessing mechanical catheter dysfunction in automated tidal peritoneal dialysis using cycler software: a case control, proof-of-concept study

被引:0
|
作者
Krystell Oviedo Flores
Lukas Kaltenegger
Fabian Eibensteiner
Markus Unterwurzacher
Klaus Kratochwill
Christoph Aufricht
Franz König
Andreas Vychytil
机构
[1] Medical University of Vienna,Division of Nephrology and Dialysis, Department of Medicine III
[2] Baxter Healthcare GmbH,Division of Pediatric Nephrology and Gastroenterology, Department of Pediatrics and Adolescent Medicine, Comprehensive Center for Pediatrics
[3] Medical University of Vienna,Christian Doppler Laboratory for Molecular Stress Research in Peritoneal Dialysis
[4] Medical University of Vienna,Center for Medical Statistics, Informatics and Intelligent Systems
[5] Medical University of Vienna,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
New recommendations on evaluation of peritoneal membrane function suggest ruling out catheter dysfunction when evaluating patients with low ultrafiltration capacity. We introduce the use of a combination of parameters obtained from the cycler software PD Link with HomeChoicePro (Baxter International Inc., Illinois, United States) cyclers for predicting catheter dysfunction in automated peritoneal dialysis patients (APD). Out of 117 patients treated at the Medical University of Vienna between 2015 and 2021, we retrospectively identified all patients with verified catheter dysfunction (n = 14) and compared them to controls without clinical evidence of mechanical catheter problems and a recent X-ray confirming PD catheter tip in the rectovesical/rectouterine space (n = 19). All patients had a coiled single-cuff PD catheter, performed tidal PD, and received neutral pH bicarbonate/lactate-buffered PD fluids with low-glucose degradation products on APD. Icodextrin-containing PD fluids were used for daytime dwells. We retrieved cycler data for seven days each and tested parameters' predictive capability of catheter dysfunction. Total number of alarms/week > 7 as single predictive parameter of catheter dislocation identified 85.7% (sensitivity) of patients with dislocated catheter, whereas 31.6% (1-specificity) of control patients were false positive. A combination of parameters (number of alarms/week > 7, total drain time > 22 min, ultrafiltration of last fill < 150 mL) where at least two of three parameters appeared identified the same proportion of patients with catheter dislocation, but was more accurate in identifying controls (21.1% false positive). In contrast to yearly PET measurements, an easily applicable combination of daily cycler readout parameters, also available in new APD systems connected to remote monitoring platforms shows potential for diagnosis of catheter dysfunction during routine follow-up.
引用
收藏
相关论文
共 48 条
  • [31] Clinical and Biochemical Characteristics of COVID-19-Associated Acute Kidney Injury (COVAKI): A Proof-of-Concept Case-Control Study
    Kumthekar, Girish V.
    Nagarkar, Manasi S.
    Purandare, Veena
    Shukla, Sharvari
    Yeravdekar, Rajiv
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [32] Global diastolic strain rate for the assessment of left ventricular diastolic dysfunction in young peritoneal dialysis patients: a case control study
    Zhu, Jing
    Shi, Fei
    You, Tao
    Tang, Chao
    Chen, Jianchang
    BMC NEPHROLOGY, 2020, 21 (01)
  • [33] Global diastolic strain rate for the assessment of left ventricular diastolic dysfunction in young peritoneal dialysis patients: a case control study
    Jing Zhu
    Fei Shi
    Tao You
    Chao Tang
    Jianchang Chen
    BMC Nephrology, 21
  • [34] Feasibility and Efficacy of Targeted Cardiac NF-kB Inhibition in Experimental Diastolic Dysfunction Using Drug-Delivery Technology: A Proof-of-Concept Study
    Chade, Alejandro R.
    Eirin, Alfonso
    Bidwell, Gene L.
    CIRCULATION, 2021, 144
  • [35] A novel approach of using brachial plexus blockade as an experimental model for diagnosis of intraoperative nerve dysfunction with somatosensory evoked potentials: a blinded proof-of-concept study
    Chui, Jason
    Freytag, Alex
    Glimore, Greydon
    Dhir, Shalini
    Rachinsky, Max
    Murkin, John
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2021, 68 (07): : 1018 - 1027
  • [36] Accuracy of GynTect® Methylation Markers to Detect Recurrent Disease in Patients Treated for CIN3: A Proof-of-Concept Case-Control Study
    Hoyer, Heike
    Scheungraber, Cornelia
    Mehlhorn, Grit
    Hagemann, Ingke
    Scherbring, Sarah
    Woelber, Linn
    Petzold, Annett
    Wunsch, Kristina
    Schmitz, Martina
    Hampl, Monika
    Boehmer, Gerd
    Hillemanns, Peter
    Runnebaum, Ingo B.
    Duerst, Matthias
    CANCERS, 2024, 16 (17)
  • [37] Real-time Noninvasive Monitoring of Intracranial Fluid Shifts During Dialysis Using Volumetric Integral Phase-Shift Spectroscopy (VIPS): A Proof-of-Concept Study
    Rao, Chethan P. Venkatasubba
    Bershad, Eric M.
    Calvillo, Eusebia
    Maldonado, Nelson
    Damani, Rahul
    Mandayam, Sreedhar
    Suarez, Jose I.
    NEUROCRITICAL CARE, 2018, 28 (01) : 117 - 126
  • [38] Real-time Noninvasive Monitoring of Intracranial Fluid Shifts During Dialysis Using Volumetric Integral Phase-Shift Spectroscopy (VIPS): A Proof-of-Concept Study
    Chethan P. Venkatasubba Rao
    Eric M. Bershad
    Eusebia Calvillo
    Nelson Maldonado
    Rahul Damani
    Sreedhar Mandayam
    Jose I. Suarez
    Neurocritical Care, 2018, 28 : 117 - 126
  • [39] Repeat-dose toxicity prediction with Generalized Read-Across (GenRA) using targeted transcriptomic data: A proof-of-concept case study
    Tate, Tia
    Wambaugh, John
    Patlewicz, Grace
    Shah, Imran
    COMPUTATIONAL TOXICOLOGY, 2021, 19
  • [40] Vaginal miR-210-3p as a potential biomarker for pregnancies complicated by early fetal growth restriction: A proof-of-concept case-control study
    Bigagli, Elisabetta
    Spataro, Elisa
    Pasquini, Lucia
    Cinci, Lorenzo
    D'Ambrosio, Mario
    De Blasi, Chiara
    Bartolini, Chiara
    Petraglia, Felice
    Luceri, Cristina
    PLACENTA, 2025, 163 : 8 - 15