Purpose. Fibrin glue is effective for maintaining hemostasis after anastomosis and for filling needle holes after cardiothoracic and vascular surgery, but few experimental studies concerning methods of application to obtain more effective hemostasis have been reported. Methods. Bolheal was used as the fibrin glue. Fibrinogen solution (A, 0.3 ml) and thrombin solution (B, 0.3 ml), components of fibrin glue, were applied to the needle holes by the following four methods: group 1 (n = 8), drip method; group 2 (n = 8), spray method; group 3 (n = 8), rub-and-spray method; group 4 (n = 8), rub-andrub method. Additional studies were done in groups 3 and 4 to evaluate the hemostatic effect with different curing times and temperatures. Results. The pressure at which the fibrin sealant ruptured were significantly higher in group 3 (109 ± 16 mmHg) and group 4 (113 ± 7) (for both groups: P < 0.05 vs. group 1 (22 ± 8) and group 2 (64 ± 10)). The pressure increased with prolongation of the curing time, and significant differences were noted between the pressures at = 2 min and that at 30 s (both groups: P < 0.05 vs. 30 s). The curing temperature had no significant influence in the two groups. Microscopically, the glue effectively plugged the needle holes in groups 3 and 4 Conclusion. Compared with the current drip and spray methods, more effective hemostasis was obtained by rubbing on the fibrin glue. © The Japanese Association for Thoracic Surgery 2012.
引用
收藏
页码:140 / 144
页数:4
相关论文
共 50 条
  • [1] Experimental study on effective application of fibrin glue
    Kin, Hajime
    Nakajima, Takayuki
    Okabayashi, Hitoshi
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2012, 60 (03) : 140 - 144
  • [2] Microneural anastomosis with fibrin glue: An experimental study
    Suri, A
    Mehta, VS
    Sarkar, C
    NEUROLOGY INDIA, 2002, 50 (01) : 23 - 26
  • [3] New application method of fibrin glue for more effective hemostasis in cardiovascular surgery: Rub-and-spray method
    Minato N.
    Shimokawa T.
    Katayama Y.
    Yamada N.
    Sakaguchi M.
    Itoh M.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2004, 52 (8) : 361 - 366
  • [4] WATERTIGHT SUTURES WITH FIBRIN GLUE - AN EXPERIMENTAL-STUDY
    OOSTERLINCK, W
    CHENG, H
    HOEBEKE, P
    VERBEECK, R
    EUROPEAN UROLOGY, 1993, 23 (04) : 481 - 484
  • [5] Possibilities and limitations of fibrin glue usage in nephron-sparing surgery: Experimental study
    Stojkovic, I
    Savic, V
    Djokic, M
    Balint, B
    Ljubenovic, S
    Ignjatovic, I
    UROLOGIA INTERNATIONALIS, 2005, 74 (04) : 355 - 360
  • [6] Experimental Study on the Viscosity and Adhesive Performance of Exogenous Liquid Fibrin Glue
    Hayashi, Takuro
    Hasegawa, Mitsuhiro
    Inamasu, Joji
    Adachi, Kazuhide
    Nagahisa, Shinya
    Hirose, Yuichi
    NEUROLOGIA MEDICO-CHIRURGICA, 2014, 54 (11) : 895 - 900
  • [7] Combined use of hair and fibrin glue for soft tissue augmentation:: Experimental study
    Uysal, Afsin
    Ulusoy, Mustafa Guerhan
    Sungur, Nezih
    Karaaslan, Oender
    Kocer, Ugur
    Soekmensueer, Lale Karakoc
    AESTHETIC PLASTIC SURGERY, 2006, 30 (04) : 469 - 473
  • [8] Conventional versus fibrin-glue-augmented arterial microanastomosis: An experimental study
    Le Hanneur, M.
    Chaves, C.
    Lauthe, O.
    Salabi, V.
    Bouche, P. -A.
    Fitoussi, F.
    HAND SURGERY & REHABILITATION, 2022, 41 (05) : 569 - 575
  • [9] Combined Use of Hair and Fibrin Glue for Soft Tissue Augmentation: Experimental Study
    Afşin Uysal
    Mustafa Gürhan Ulusoy
    Nezih Sungur
    Önder Karaaslan
    Uğur Koçer
    Lale Karakoç Sökmensüer
    Cenk Sökmensüer
    Aesthetic Plastic Surgery, 2006, 30 : 469 - 473
  • [10] Arthroscopic meniscal repair using fibrin glue .1. Experimental study
    Ishimura, M
    Ohgushi, H
    Habata, T
    Tamai, S
    Fujisawa, Y
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1997, 13 (05) : 551 - 557