Video double-lumen tube for one lung ventilation: implementation and experience in 343 cases of routine clinical use during the first 20 months of the SARS-CoV-2 pandemic

被引:1
作者
Irouschek, Andrea [1 ,3 ]
Schmidt, Joachim [1 ]
Birkholz, Torsten [1 ]
Sirbu, Horia [2 ]
Moritz, Andreas [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nuremberg, Univ Hosp Erlangen, Fac Med, Dept Anesthesiol, Erlangen, Germany
[2] Friedrich Alexander Univ Erlangen Nuremberg, Univ Hosp Erlangen, Fac Med, Dept Thorac Surg, Erlangen, Germany
[3] Univ Hosp Erlangen, Dept Anesthesiol, Krankenhausstr 12, D-91054 Erlangen, Germany
关键词
One lung ventilation; Thoracic surgery; Double-lumen tube; Video double-lumen tube; SARS-CoV-2; FIBEROPTIC BRONCHOSCOPY; THORACIC ANESTHESIA; ADULT PATIENTS; PREDICTION; HYPOXEMIA;
D O I
10.1186/s13019-024-02663-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Double-lumen tubes (DLTs) are the preferred device for lung isolation. Conventional DLTs (cDLT) need a bronchoscopic position control. Visualisation of correct DLT positioning could be facilitated by the use of a video double-lumen tube (vDLT). During the SARS-CoV-2-pandemic, avoiding aerosol-generation was suggesting using this device. In a large retrospective series, we report both general and pandemic related experiences with the device.Methods All anesthesia records from patients aged 18 years or older undergoing surgery from April 1st, 2020 to December 31st, 2021 in the department of thoracic surgery requiring intraoperative lung isolation were analyzed retrospectively.Results During the investigation period 343 left-sided vDLTs (77.4%) and 100 left-sided cDLTs (22.6%) were used for one lung ventilation. In the vDLT group bronchoscopy could be reduced by 85.4% related to the cDLT group. Additional bronchoscopy to reach or maintain correct position was needed in 11% of the cases. Other bronchoscopy indications occured in 3.6% of the cases. With cDLT, in 1% bronchoscopy for other indications than conforming position was observed.Conclusions The Ambu (R) VivaSight (TM) vDLT is an efficient, easy-to-use and safe airway device for the generation of one lung ventilation in patients undergoing thoracic surgery. The vDLT implementation was achieved easily with full interchangeability to the left-sided cDLT. Using the vDLT can reduce the need for aerosol-generating bronchoscopic interventions by 85.4%. Continuous video view to the carina enabling position monitoring of the DLT without need for bronchoscopy might be beneficial for both employee's and patient's safety.
引用
收藏
页数:9
相关论文
共 31 条
[1]  
[Anonymous], 2020, WHO Director-General's opening remarks at the media briefing on COVID-19
[2]  
[Anonymous], WHO Director-General's statement on IHR Emergency Committee on Novel Coronavirus. (2019-nCoV)2020
[3]   The German Perioperative Procedural Time Glossary (2020 Edition*) A joint recommendation by the BDA, BDC, VOPM, VOPMO, OGARI and SFOPM [J].
Bauer, M. ;
Auhuber, T. C. ;
Kraus, R. ;
Rueggeberg, J. ;
Wardemann, K. ;
Mueller, P. ;
Taube, C. ;
Diemer, M. ;
Schuster, M. .
ANASTHESIOLOGIE & INTENSIVMEDIZIN, 2020, 61 :516-531
[4]   Consensus statement: Safe Airway Society principles of airway management and tracheal intubation specific to the COVID-19 adult patient group [J].
Brewster, David J. ;
Groombridge, Christopher J. ;
Gatward, Jonathan J. .
MEDICAL JOURNAL OF AUSTRALIA, 2021, 214 (01) :46-U33
[5]   Intubation with Vivasight Double-Lumen Tube Versus Conventional Double-Lumen Tube in Adult Patients Undergoing Lung Resection: A Retrospective Analysis [J].
Granell, Manuel ;
Petrini, Giulia ;
Kot, Pablo ;
Murcia, Mercedes ;
Morales, Javier ;
Guijarro, Ricardo ;
de Andres, Jose A. .
ANNALS OF CARDIAC ANAESTHESIA, 2022, 25 (03) :279-285
[6]   A Randomized Controlled Study of the Use of Video Double-Lumen Endobronchial Tubes Versus Double-Lumen Endobronchial Tubes in Thoracic [J].
Heir, Jagtar Singh ;
Guo, Shu-Lin ;
Purugganan, Ronaldo ;
Jackson, Tim A. ;
Sekhon, Anupamjeet Kaur ;
Mirza, Kazim ;
Lasala, Javier ;
Feng, Lei ;
Cata, Juan P. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (01) :267-274
[7]   A Retrospective Evaluation of the Use of Video-Capable Double-Lumen Endotracheal Tubes in Thoracic Surgery [J].
Heir, Jagtar Singh ;
Purugganan, Ron ;
Jackson, Timothy A. ;
Norman, Peter H. ;
Cata, Juan P. ;
Kosturakis, Alyssa ;
Thakar, Dilip .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2014, 28 (04) :870-872
[8]   Double lumen tube location predicts tube malposition and hypoxaemia during one lung ventilation [J].
Inoue, S ;
Nishimine, N ;
Kitaguchi, K ;
Furuya, H ;
Taniguchi, S .
BRITISH JOURNAL OF ANAESTHESIA, 2004, 92 (02) :195-201
[9]   COVID-19 safety: aerosol-generating procedures and cardiothoracic surgery and anaesthesia - Australian and New Zealand consensus statement [J].
Irons, Joanne F. ;
Pavey, Warren ;
Bennetts, Jayme S. ;
Granger, Emily ;
Tutungi, Elli ;
Almeida, Aubrey .
MEDICAL JOURNAL OF AUSTRALIA, 2021, 214 (01) :40-44
[10]   Hypoxemia during One-lung Ventilation Prediction, Prevention, and Treatment [J].
Karzai, Waheedullah ;
Schwarzkopf, Konrad .
ANESTHESIOLOGY, 2009, 110 (06) :1402-1411