A method to assess the accuracy of sonotubometry for detecting Eustachian tube openings

被引:0
|
作者
J. Douglas Swarts
Miriam S. Teixeira
Juliane Banks
Jenna El-Wagaa
William J. Doyle
机构
[1] University of Pittsburgh,Department of Otolaryngology
[2] School of Medicine,undefined
来源
European Archives of Oto-Rhino-Laryngology | 2015年 / 272卷
关键词
Eustachian tube; Adults; Sonotubometry; Methodology;
D O I
暂无
中图分类号
学科分类号
摘要
Sonotubometry is a simple test for Eustachian tube (ET) opening during a maneuver. Different sonotubometry configurations were suggested to maximize test accuracy, but no method has been described for comparing sonotubometry test results with those for a definitive measure of ET opening. Here, we present such a method and exemplify is use by an accuracy assessment of a simple sonotubometry configuration. A total of 502 data-sequences from 168 test sessions in 103 adult subjects were analyzed. For each session, subjects were seated in a pressure chamber and relative middle ear over- and under-pressures created by changing chamber pressure. At each pressure, the test sequence of bilateral tympanometry, bilateral sonotubometry while the subject swallowed twice, and bilateral tympanometry was done. Tympanometric data were expressed as the fractional gradient equilibrated (FGE) by swallowing and sonotubometric signals were analyzed to record the shape of detected sound signals. Tympanometric and sonotubometric tubal opening assignments were analyzed by cross-correlation. For the data sequences with FGE = 0 (n = 32) evidencing no tubal opening and one (n = 249) evidencing definitive tubal opening, detection of a sonotubometry sound signal during a swallow had a sensitivity and specificity of 74.2 and 65.6 % for identifying ET openings and an accuracy of 73.3 % for assigning ET opening/non-opening by swallowing. Measures of sound signal shape were significantly different between those groups. This protocol allows a sonotubometry accuracy assessment for detecting ET openings. For the test configuration used, accuracy was moderate, but this should improve as more sophisticated sonotubometry test configurations are evaluated.
引用
收藏
页码:2111 / 2119
页数:8
相关论文
共 25 条
  • [1] A method to assess the accuracy of sonotubometry for detecting Eustachian tube openings
    Swarts, J. Douglas
    Teixeira, Miriam S.
    Banks, Juliane
    El-Wagaa, Jenna
    Doyle, William J.
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2015, 272 (09) : 2111 - 2119
  • [2] Synchronous Endoscopy and Sonotubometry of the Eustachian Tube: A Pilot Study
    Handzel, Ophir
    Poe, Dennis
    Marchbanks, Robert J.
    OTOLOGY & NEUROTOLOGY, 2012, 33 (02) : 184 - 191
  • [3] Correlations between videoendoscopy and sonotubometry of eustachian tube opening during a swallow
    Alper, Cuneyt M.
    Teixeira, Miriam S.
    Swarts, J. Douglas
    LARYNGOSCOPE, 2016, 126 (12) : 2778 - 2784
  • [4] Eustachian tube opening measured by sonotubometry is poorer in adults with a history of past middle ear disease
    Teixeira, Miriam S.
    Banks, Juliane
    Swarts, J. Douglas
    Alper, Cuneyt M.
    Doyle, William J.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2014, 78 (04) : 593 - 598
  • [5] Sound and Noise Sources in Sonotubometry: An Investigation of Eustachian Tube Assessment
    Nava, Tobia Sebastiano
    Nussbaumer, Maximilian
    Tysome, James R.
    Sutcliffe, Michael P. F.
    ANNALS OF BIOMEDICAL ENGINEERING, 2024, 52 (08) : 2247 - 2257
  • [6] Reproducibility of sonotubometry as Eustachian tube ventilatory function test in healthy children
    van der Avoort, Stijn J. C.
    van Heerbeek, Niels
    Snik, Ad F. M.
    Zielhuis, Gerhard A.
    Cremers, Cor W. R. J.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2007, 71 (02) : 291 - 295
  • [7] Results of sonotubometry in testing eustachian tube ventilatory function in children with cleft palate
    van der Avoort, Stijn J. C.
    van Heerbeek, Niels
    Admiraal, Ronald J. C.
    Zielhuis, Gerhard A.
    Cremers, Cor W. R. J.
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2008, 117 (05) : 335 - 340
  • [8] Digital Signal Processing for Knowledge Based Sonotubometry of Eustachian Tube Function
    Borangiu, Andrei
    Popescu, Dan
    CONTROL ENGINEERING AND APPLIED INFORMATICS, 2014, 16 (03): : 56 - 64
  • [9] Eustachian Tube Opening Measurement by Sonotubometry Using Perfect Sequences for Healthy Adults
    Beleskiene, Vilma
    Lesinskas, Eugenijus
    Januskiene, Vaida
    Daunoraviciene, Kristina
    Rauba, Darius
    Ivaska, Justinas
    CLINICAL AND EXPERIMENTAL OTORHINOLARYNGOLOGY, 2016, 9 (02) : 116 - 122
  • [10] A Novel Eustachian Tube Test: Preliminary Research of Sonotubometry With Nasopharynx Under Pressure
    Li, Jingyu
    Ruan, Kaian
    Tan, Songhua
    Xie, Lihong
    Liu, Lei
    Liu, Xinmiao
    Tang, Anzhou
    OTOLOGY & NEUROTOLOGY, 2022, 43 (05) : 580 - 586