A novel ZnO/reduced graphene oxide and Prussian blue modified carbon paste electrode for the sensitive determination of Rutin

被引:0
作者
Ozma J D’Souza
Ronald J Mascarenhas
Ashis K Satpati
Basavanakote M Basavaraja
机构
[1] Bharathiar University,Research and Development Centre
[2] St. Joseph’s College,Electrochemistry Research Group, Department of Chemistry
[3] Bhabha Atomic Research Centre,Analytical Chemistry Division
[4] Anushakthi Nagar,Department of Chemistry
[5] Trombay,undefined
[6] PES University,undefined
来源
Science China Chemistry | 2019年 / 62卷
关键词
Rutin; zinc oxide nanoparticles; reduced graphene oxide; Prussian blue; modified carbon paste electrode; ascorbic acid;
D O I
暂无
中图分类号
学科分类号
摘要
A carbon paste modified sensor based on a novel composite of zinc oxide nanoparticles deposited on reduced graphene oxide (ZnO-rGrO) and Prussian blue (PB) was drop-cast (ZnO-rGrO-PB/MCPE) for the sensitive estimation of Rutin (Rtn) at pH 7.0. The high surface area of ZnO-rGrO and electrocatalytic property of PB promotes the oxidation of Rtn. Field emission scanning electron microscope (FE-SEM) and energy-dispersive X-ray spectroscopy (EDX) techniques were employed to confirm the deposition of ZnO-rGrO and PB on carbon paste electrode (CPE). The ability of ZnO-rGrO-PB/MCPE in charge transfer at the interface was investigated using electrochemical impedance spectroscopy (EIS). The heterogeneous rate constant (ks) and the charge transfer coefficient (α) have been calculated as 6.08 s−1 and 0.74 respectively. This sensor showed a wide linear response for Rtn from 7.0×10−8 to 7.0×10−6 M and 7.0×10−6 to 1.0×10−4 M with a limit of detection (2.05±0.04)×10−8 M (S/N=3). The application of ZnO-rGrO-PB/MCPE was found in the analysis of Rtn in fruit juice samples using standard addition method. This sensor showed good reproducibility, stability, selectivity and sensitivity.
引用
收藏
页码:262 / 270
页数:8
相关论文
共 229 条
[1]  
Gullón B(2017)undefined Trends Food Sci Tech 67 220-235
[2]  
Lú-Chau TA(2010)undefined Pol J Food Nutr Sci 60 315-321
[3]  
Moreira MT(2000)undefined Eur Rev Med Pharmacol Sci 4 21-24
[4]  
Lema JM(2015)undefined Osteoarthritis Cartilage 23 94-102
[5]  
Eibes G(2016)undefined Spectrochim Acta Mol Biomol Spectrosc 169 82-86
[6]  
Zielinska D(2016)undefined Anal Methods 8 4056-4063
[7]  
Szawara-Nowak D(2009)undefined J Serb Chem Soc 74 1021-1033
[8]  
Zielinski H(2015)undefined Sens Actuators B-Chem 206 126-132
[9]  
Squadrito F(2008)undefined J Pharm Biomed Anal 48 1326-1331
[10]  
Altavilla D(2018)undefined J Electroanal Chem 811 78-83