Poly-l-lactide Polymer-Based Triple Drug-Eluting Stent with Abciximab, Alpha-Lipoic Acid and Sirolimus in Porcine Coronary Restenosis Model

被引:0
作者
Jun-Kyu Park
Sung Soo Kim
Hyun Kuk Kim
Jae-Woon Nah
Han Byul Kim
In Ho Bae
Dae Sung Park
Jae Won Shim
Min Young Lee
Joong Sun Kim
Bon-Sang Koo
Kang-Jin Jeong
Yeong Bae Jin
Sun-Uk Kim
Sang-Rae Lee
Joo-Young Na
Doo Sun Sim
Young Joon Hong
Kyung Seob Lim
Myung Ho Jeong
机构
[1] CGBio Co. Ltd,Department of Internal Medicine and Cardiovascular Center
[2] Chosun University Hospital,Department of Polymer Science and Engineering
[3] University of Chosun College of Medicine,Cardiovascular Research Center
[4] Sunchon National University,Research Institute of Medical Sciences
[5] Chonnam National University Hospital,College of Pharmacy, Research Institute of Pharmaceutical Sciences
[6] Korea Cardiovascular Stent Research Institute,Herbal Medicine Research Division
[7] Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea Ministry of Health and Welfare,Futuristic Animal Resource and Research Center & National Primate Research Center
[8] Chonnam National University,Biomedical Research Institute
[9] Kyungpook National University,undefined
[10] Korea Institute of Oriental Medicine,undefined
[11] Korea Research Institute of Bioscience and Biotechnology,undefined
[12] Chonnam National University Hospital,undefined
来源
Macromolecular Research | 2020年 / 28卷
关键词
polymer; drug-eluting stents; neointimal hyperplasia; percutaneous coronary intervention; restenosis; inflammation;
D O I
暂无
中图分类号
学科分类号
摘要
This study evaluated the effect of a novel triple drug-eluting stent containing antithrombotic abciximab, antioxidative alpha-lipoic acid (ALA), and antiproliferative sirolimus in a porcine model. The coronary arteries of pigs were randomized into three groups: triple drug-eluting stent (TES; n=10), sirolimus-eluting stent (SES; n=10), and bare metal stent (BMS; n=10). At 28 days after stent implantation, a histopathologic analysis was performed. There were no significant differences in the injury score. There were significant differences in the neointimal area (2.3±0.6 mm2 in TES vs. 2.5±0.88 mm2 in SES vs. 3.3±0.58 mm2 in BMS, p<0.0001), percent area of stenosis (37.1±9.26% in TES vs. 46.1±15.9% in SES vs. 66.2±10.12% in BMS, p<0.0001), inflammation score (1.0 [range, 0.0-1.0] in TES vs. 1.5 [range, 1.0-2.0] in SES vs. 1.0 [range, 1.0-2.0] in BMS, p<0.05), and fibrin score (2.0 [range, 1.0-2.0] in TES vs. 2.0 [range, 1.0-2.5] in SES vs. 0.0 [range, 0.0-1.0] in BMS, p<0.0001) among the three groups. The occlusion rates using micro-computed tomography showed similar restenosis rates based on histologic analysis (35.4±8.39% in TES vs. 43.4±10.12% in SES vs. 71.4±4.38% in BMS, p<0.0001). TES demonstrated an inhibitory effect on the smooth muscle cells compared to the other stents. It also suppressed inflammation in the stented lesion compared to SES as evidenced by the inflammation score.
引用
收藏
页码:9 / 14
页数:5
相关论文
共 419 条
[41]  
Fahy M(undefined)undefined undefined undefined undefined-undefined
[42]  
Pocock S J(undefined)undefined undefined undefined undefined-undefined
[43]  
Mehran R(undefined)undefined undefined undefined undefined-undefined
[44]  
Leon M B(undefined)undefined undefined undefined undefined-undefined
[45]  
Kretov E(undefined)undefined undefined undefined undefined-undefined
[46]  
Narsyhkin I(undefined)undefined undefined undefined undefined-undefined
[47]  
Baystrukov V(undefined)undefined undefined undefined undefined-undefined
[48]  
Grahzdankin I(undefined)undefined undefined undefined undefined-undefined
[49]  
. Prohkorikhin A(undefined)undefined undefined undefined undefined-undefined
[50]  
Zubarev D(undefined)undefined undefined undefined undefined-undefined