Evaluation of corneal biomechanics in patients with keratectasia following LASIK using dynamic Scheimpflug analyzer

被引:0
|
作者
Ryotaro Ueki
Naoyuki Maeda
Mutsumi Fuchihata
Tomoko Asai
Shizuka Koh
Hisataka Fujimoto
Masafumi Uematsu
Kohji Nishida
机构
[1] Osaka University Graduate School of Medicine,Department of Ophthalmology
[2] Nagasaki University,Department of Ophthalmology and Visual Sciences, Graduate School of Biomedical Sciences
来源
Japanese Journal of Ophthalmology | 2018年 / 62卷
关键词
Keratectasia; LASIK; Keratoconus; Biomechanics; Dynamic Scheimpflug analyzer;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:443 / 450
页数:7
相关论文
共 50 条
  • [21] Effect of prostaglandin analogues on the biomechanical corneal properties in patients with open-angle glaucoma and ocular hypertension measured with dynamic scheimpflug analyzer
    Isabel Martinez-Sanchez, Marta
    Bolivar, Gema
    Sideroudi, Haris
    Teus, Miguel A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (12) : 3927 - 3933
  • [22] Effect of prostaglandin analogues on the biomechanical corneal properties in patients with open-angle glaucoma and ocular hypertension measured with dynamic scheimpflug analyzer
    Marta Isabel Martínez-Sánchez
    Gema Bolívar
    Haris Sideroudi
    Miguel A. Teus
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2022, 260 : 3927 - 3933
  • [23] Comparison of corneal dynamic parameters and tomographic measurements using Scheimpflug imaging in keratoconus
    Chan, Tommy C. Y.
    Wang, Yu Meng
    Yu, Marco
    Jhanji, Vishal
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (01) : 42 - 47
  • [24] Comparison of Posterior Corneal Imaging Before and After LASIK Using Dual Rotating Scheimpflug and Scanning Slit-Beam Corneal Tomography Systems
    Sy, Mary Ellen
    Ramirez-Miranda, Arturo
    Zarei-Ghanavati, Siamak
    Engle, Jamison
    Danesh, Jennifer
    Hamilton, D. Rex
    JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (02) : 96 - 101
  • [25] Evaluation of changes in corneal biomechanical properties by Ocular Response Analyzer after femtosecond laser assisted LASIK
    Kucumen, Raciha Beril
    Yenerel, Nursal Melda
    Gorgun, Ebru
    Kohen, Maryo Cenk
    Basar, Demir
    Alimgil, Murat Levent
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2009, 39 (04): : 250 - 255
  • [26] Corneal Biomechanics Using a Scheimpflug-Based Noncontact Device in Normal-Tension Glaucoma and Healthy Controls
    Hong, Karen
    Wong, Ian Y. H.
    Singh, Kuldev
    Chang, Robert T.
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2019, 8 (01): : 22 - 29
  • [27] Corneal biomechanical properties after soft contact lens wear measured on a dynamic Scheimpflug analyzer: A before and after study
    Peyman, A.
    Ghoreishi, M.
    Hashemi-Estabragh, S-S
    Mirmohammadkhani, M.
    Mohammadinia, M.
    Pourazizi, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2021, 44 (03): : 391 - 396
  • [28] Evaluation of corneal changes after myopic LASIK using the Pentacam (R)
    Khairat, Yehia M.
    Mohamed, Yasser H.
    Moftah, Ismail A. N. O.
    Fouad, Narden N.
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 1771 - 1776
  • [29] New parameters for evaluating corneal biomechanics and intraocular pressure after small-incision lenticule extraction an by Scheimpflug-based dynamic tonometry
    Fernandez, Joaquin
    Rodriguez-Vallejo, Manuel
    Martinez, Javier
    Tauste, Ana
    Salvestrini, Patrizia
    Pinero, David P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (06) : 803 - 811
  • [30] Evaluation of Anterior Segment Parameters and Possible Influencing Factors in Normal Subjects Using a Dual Scheimpflug Analyzer
    Wang, Xiaogang
    Dong, Jing
    Wu, Qiang
    PLOS ONE, 2014, 9 (05):