A robust sliding mode controller with internal model for closed-loop artificial pancreas

被引:0
|
作者
Amjad Abu-Rmileh
Winston Garcia-Gabin
Darine Zambrano
机构
[1] University of Girona,Department of Electrical, Electronics and Control Engineering
关键词
Artificial pancreas; Internal model control; Sliding mode control; Type-1 diabetes mellitus;
D O I
暂无
中图分类号
学科分类号
摘要
The study presents a robust closed-loop sliding mode controller with internal model for blood glucose control in type-1 diabetes. Type-1 diabetic patients depend on external insulin delivery to keep their blood glucose within near-normal ranges. Closed-loop artificial pancreas is developed to help avoid dangerous, potentially life-threatening hypoglycemia, as well as to prevent complication-inducing hyperglycemia. The proposed controller is designed using a combination of sliding mode and internal model control techniques. To enhance postprandial performance, a feedforward controller is added to inject insulin bolus. Simulation studies have been performed to test the controller, which revealed that the proposed control strategy is able to control the blood glucose well within the safe limits in the presence of meals and measurements errors. The controller shows acceptable robustness against changes in insulin sensitivity, model–patient mismatch, and errors in estimating meal’s contents.
引用
收藏
页码:1191 / 1201
页数:10
相关论文
共 50 条
  • [21] A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
    El-Khatib, Firas H.
    Russell, Steven J.
    Nathan, David M.
    Sutherlin, Robert G.
    Damiano, Edward R.
    SCIENCE TRANSLATIONAL MEDICINE, 2010, 2 (27) : 27ra27
  • [22] Closed-loop artificial pancreas: current studies and promise for the future
    Weinzimer, Stuart A.
    CURRENT OPINION IN ENDOCRINOLOGY DIABETES AND OBESITY, 2012, 19 (02) : 88 - 92
  • [23] Security Challenges and Solutions for Closed-Loop Artificial Pancreas Systems
    Lazaro, Caterina
    Oruklu, Erdal
    Cinar, Ali
    2017 IEEE 60TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2017, : 1097 - 1100
  • [24] The Impact of Insulin Pharmacokinetics and Pharmacodynamics on the Closed-loop Artificial Pancreas
    Lee, Justin J.
    Dassau, Eyal
    Zisser, Howard
    Tamborlane, William
    Weinzimer, Stuart
    Doyle, Francis J., III
    2013 IEEE 52ND ANNUAL CONFERENCE ON DECISION AND CONTROL (CDC), 2013, : 127 - 132
  • [25] Closed-Loop Artificial Pancreas Therapy for Type 1 Diabetes
    Zhou, Keren
    Isaacs, Diana
    CURRENT CARDIOLOGY REPORTS, 2022, 24 (09) : 1159 - 1167
  • [26] The Impact of Glucose Sensing Dynamics on the Closed-Loop Artificial Pancreas
    Huyett, Lauren M.
    Dassau, Eyal
    Zisser, Howard C.
    Doyle, Francis J., II
    2015 AMERICAN CONTROL CONFERENCE (ACC), 2015, : 5116 - 5121
  • [27] Challenges and recent progress in the development of a closed-loop artificial pancreas
    Bequette, B. Wayne
    ANNUAL REVIEWS IN CONTROL, 2012, 36 (02) : 255 - 266
  • [28] The Artificial Pancreas HOW CLOSED-LOOP CONTROL IS REVOLUTIONIZING DIABETES
    Haidar, Ahmad
    IEEE CONTROL SYSTEMS MAGAZINE, 2016, 36 (05): : 28 - +
  • [29] A safe-enhanced fully closed-loop artificial pancreas controller based on deep reinforcement learning
    Zhao, Yan Feng
    Chaw, Jun Kit
    Ang, Mei Choo
    Tew, Yiqi
    Shi, Xiao Yang
    Liu, Lin
    Cheng, Xiang
    PLOS ONE, 2025, 20 (01):
  • [30] CLINICAL TEST OF A FUZZY LOGIC CONTROLLER (FLC) IN A FULLY AUTOMATED CLOSED-LOOP ARTIFICIAL PANCREAS (AP)
    Mauseth, R.
    Matheson, D.
    Kircher, R.
    Bollyky, J.
    Greenbaum, C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A16 - A16