In this paper, a review is presented on the experimental investigations and the numerical simulations performed to analyze the thermal-hydraulic performance of the air-cooled heat exchangers. The air-cooled heat exchangers mostly consist of the finned-tube bundles. The primary role of the extended surfaces (fins) is to provide more heat transfer area to enhance the rate of heat transfer on the air side. The secondary role of the fins is to generate vortices, which help in enhancing the mixing and the heat transfer coefficient. In this study, the annular and plate fins are considered, the annular fins are further divided into four categories: (1) plane annular fins, (2) serrated fins, (3) crimped spiral fins, (4) perforated fins, and similarly for the plate fins, the fin types are: (1) plain plate fins, (2) wavy plate fins, (3) plate fins with DWP, and (4) slit and strip fins. In Section 4, the performance of the various types of fins is presented with respect to the parameters: (1) Reynolds number, (2) fin pitch, (3) fin height, (4) fin thickness, (5) tube diameter, (6) tube pitch, (7) tube type, (8) number of tube rows, and (9) effect of dehumidifying conditions. In Section 5, the conclusions and the recommendations for the future work have been given.
引用
收藏
页码:673 / 755
页数:82
相关论文
共 50 条
  • [1] A review on the thermal hydraulic characteristics of the air-cooled heat exchangers in forced convection
    Kumar, Ankur
    Joshi, Jyeshtharaj B.
    Nayak, Arun K.
    Vijayan, Pallippattu K.
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2015, 40 (03): : 673 - 755
  • [2] Air-cooled Heat Exchangers
    S Afr Mech Eng, 10 (35):
  • [3] The influence of wind on the performance of forced draught air-cooled heat exchangers
    Duvenhage, K
    Kroger, DG
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1996, 62 (2-3) : 259 - 277
  • [4] AIR-COOLED HEAT EXCHANGERS.
    Zanker, Adam
    Machine Design, 1979, 51 (28) : 158 - 166
  • [5] EFFECT OF TUBE BANK INCLINATION ON THE THERMAL HYDRAULIC PERFORMANCE OF AIR-COOLED HEAT EXCHANGERS.
    Monheit, Max
    Freim, James
    Heat Transfer Engineering, 1987, 8 (01) : 19 - 24
  • [6] QUIETER AIR-COOLED HEAT EXCHANGERS
    DRYDEN, SL
    JUDD, SH
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1970, 31 (02): : 9 - &
  • [7] Thermal Conductivity of External Contaminants of Air-Cooled Heat Exchangers
    Kuntysh V.B.
    Dudarev V.V.
    Filatov S.O.
    Korol’kova A.M.
    Chemical and Petroleum Engineering, 2017, 53 (3-4) : 244 - 247
  • [8] Investigation of heat exchanger inclination in forced-draught air-cooled heat exchangers
    Kennedy, Ian J.
    Spence, Stephen W. T.
    Spratt, Gordon R.
    Early, Juliana M.
    APPLIED THERMAL ENGINEERING, 2013, 54 (02) : 413 - 421
  • [9] Plenum chamber flow losses in forced draught air-cooled heat exchangers
    Meyer, CJ
    Kroger, DG
    APPLIED THERMAL ENGINEERING, 1998, 18 (9-10) : 875 - 893
  • [10] Effectively design air-cooled heat exchangers
    Mukherjee, R
    CHEMICAL ENGINEERING PROGRESS, 1997, 93 (02) : 26 - 47