Colloidal Gold Immunochromatographic Assay for Rapid On-Site Detection of Tetracycline in Seawater

被引:0
作者
Haiping Li
Fanping Meng
Aifeng Li
机构
[1] Ocean University of China,Key Laboratory of Marine Environment and Ecology, Ministry of Education
[2] Ocean University of China,College of Environmental Science and Engineering
来源
Journal of Ocean University of China | 2023年 / 22卷
关键词
tetracycline (TC); seawater; colloidal gold (CG); immunochromatographic assay; semi-quantitative;
D O I
暂无
中图分类号
学科分类号
摘要
Recently increasing concerns from the scientists and public have been paid for seawater pollution due to tetracycline (TC) overuse in maricultural area. However, there are few methods or instruments that can be used for specific and rapid detection of this antibiotic in seawater. In this study, the colloidal gold immunochromatographic assay (CG-ICA) was used to achieve this goal. A commercialized monoclonal antibody against TC (anti-TC mAb) was selected because of its higher sensitivity (half-maximal inhibitory concentration of 2.38 µg L−1). The prepared CG particles (average diameter of 20 nm) were used to label anti-TC mAb at pH 8.0. The conjugate pad was formed by spraying the CG-labeled anti-TC mAb on a glass fibre membrane followed by proper dryness. The test pad was made by immobilizing artificial antigen and anti-mouse mAb in the test line and the control line, respectively, in a nitrocellulose membrane. The test strip, assembled with sample pad, conjugate pad, test pad and absorbent pad, could be used to detect TC during seawater sample flowing through these components in turn. The results could be observed by the naked eye in 10 min. The visible limit of detection (vLOD) was 20 µg L−1 for TC in seawater. The CG-ICA test results were in good agreement with those of liquid chromatography-tandem mass spectrometry (LC-MS/MS). The assay also showed that, oxytetracycline (OTC) and chlortetracycline (CTC), as the structural analogues of TC, did not interfere with TC determination. Furthermore, the TC concentration given by test strip could not be affected by the fluctuation of temperature (10°C–30°C), pH (7–9) and salinity (0–40) of seawater. Therefore, CG-ICA is a suitable tool for rapid, on-site, and semi-quantitative detection of TC in seawater.
引用
收藏
页码:1129 / 1138
页数:9
相关论文
共 50 条
  • [41] Development of a highly sensitive lateral immunochromatographic assay for rapid detection of Vibrio parahaemolyticus
    Liu, Xinfeng
    Guan, Yuyao
    Cheng, Shiliang
    Huang, Yidan
    Yan, Qin
    Zhang, Jun
    Huang, Guanjun
    Zheng, Jian
    Liu, Tianqiang
    JOURNAL OF MICROBIOLOGICAL METHODS, 2016, 131 : 78 - 84
  • [42] Development of an immunochromatographic assay for rapid detection of 1-Aminohydantoin in urine specimens
    Xu, Yi Ping
    Liu, Li Qiang
    Li, Qiu Shen
    Peng, Chi Fang
    Chen, Wei
    Xu, Chuan Lai
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (03) : 308 - 314
  • [43] Matrix effect of swine urine on time-resolved fluorescent nanobeads and colloidal gold immunochromatographic assay
    Zhang, Yong
    Peng, Juan
    Guo, Ping
    Li, Guo-Qiang
    Zhang, Kai-Yi
    Lv, Xi
    Lai, Wei-Hua
    FOOD AND AGRICULTURAL IMMUNOLOGY, 2018, 29 (01) : 711 - 721
  • [44] Evaluation of a New Immunochromatographic Assay Kit for the Rapid Detection of Norovirus in Fecal Specimens
    Park, Kwi Sung
    Baek, Kyoung Ah
    Kim, Dong Uk
    Kwon, Kyung Sook
    Bing, Sun Hye
    Park, Joon Soo
    Nam, Hae Seon
    Lee, Sang Han
    Choi, Young Jin
    ANNALS OF LABORATORY MEDICINE, 2012, 32 (01) : 79 - 81
  • [45] A high selective immunochromatographic assay for rapid detection of aflatoxin B1
    Zhang, Daohong
    Li, Peiwu
    Yang, Yang
    Zhang, Qi
    Zhang, Wen
    Xiao, Zhi
    Ding, Xiaoxia
    TALANTA, 2011, 85 (01) : 736 - 742
  • [46] Interaction of Plum Pox Virus with Specific Colloidal Gold-Labeled Antibodies and Development of Immunochromatographic Assay of the Virus
    N. A. Byzova
    I. V. Safenkova
    S. N. Chirkov
    V. G. Avdienko
    A. N. Guseva
    I. V. Mitrofanova
    A. V. Zherdev
    B. B. Dzantiev
    J. G. Atabekov
    Biochemistry (Moscow), 2010, 75 : 1393 - 1403
  • [47] Development of colloidal carbon-based immunochromatographic strip for rapid detection of carbaryl in fruit juices
    Barbora Holubová-Mičková
    Martina Blažková
    Ladislav Fukal
    Pavel Rauch
    European Food Research and Technology, 2010, 231 : 467 - 473
  • [48] Development of colloidal carbon-based immunochromatographic strip for rapid detection of carbaryl in fruit juices
    Holubova-Mickova, Barbora
    Blazkova, Martina
    Fukal, Ladislav
    Rauch, Pavel
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2010, 231 (03) : 467 - 473
  • [49] Interaction of Plum Pox Virus with Specific Colloidal Gold-Labeled Antibodies and Development of Immunochromatographic Assay of the Virus
    Byzova, N. A.
    Safenkova, I. V.
    Chirkov, S. N.
    Avdienko, V. G.
    Guseva, A. N.
    Mitrofanova, I. V.
    Zherdev, A. V.
    Dzantiev, B. B.
    Atabekov, J. G.
    BIOCHEMISTRY-MOSCOW, 2010, 75 (11) : 1393 - 1403
  • [50] Gold nanoparticle–decorated metal organic frameworks on immunochromatographic assay for human chorionic gonadotropin detection
    Jing Yuan
    Xirui Chen
    Hong Duan
    Xiaoxia Cai
    Yu Li
    Liang Guo
    Xiaolin Huang
    Yonghua Xiong
    Microchimica Acta, 2020, 187