Self-Powered Implantable Skin-Like Glucometer for Real-Time Detection of Blood Glucose Level In Vivo

被引:0
作者
Wanglinhan Zhang
Linlin Zhang
Huiling Gao
Wenyan Yang
Shuai Wang
Lili Xing
Xinyu Xue
机构
[1] Northeastern University,College of Sciences
[2] Northeastern University,College of Life and Health Sciences
来源
Nano-Micro Letters | 2018年 / 10卷
关键词
Diabetes; Biosensor; Electronic-skin; Self-powered; Glucose detection; Implantable electronics;
D O I
暂无
中图分类号
学科分类号
摘要
Implantable bioelectronics for analyzing physiological biomarkers has recently been recognized as a promising technique in medical treatment or diagnostics. In this study, we developed a self-powered implantable skin-like glucometer for real-time detection of blood glucose level in vivo. Based on the piezo-enzymatic-reaction coupling effect of GOx@ZnO nanowire, the device under an applied deformation can actively output piezoelectric signal containing the glucose-detecting information. No external electricity power source or battery is needed for this device, and the outputting piezoelectric voltage acts as both the biosensing signal and electricity power. A practical application of the skin-like glucometer implanted in mouse body for detecting blood glucose level has been simply demonstrated. These results provide a new technique path for diabetes prophylaxis and treatment.[graphic not available: see fulltext]
引用
收藏
相关论文
共 311 条
[1]  
Alberti K(1998)Definition, diagnosis and classification of diabetes mellitus and its complications part 1: diagnosis and classification of diabetes mellitus—provisional report of a who consultation Diabet. Med. 15 539-553
[2]  
Zimmet PZ(2004)Global prevalence of diabetes—estimates for the year 2000 and projections for 2030 Diabetes Care 27 1047-1053
[3]  
Consultation WHO(2009)Predicting subcutaneous glucose concentration in humans: data-driven glucose modeling IEEE Trans. Biomed. Eng. 56 246-254
[4]  
Wild S(2014)Multifunctional wearable devices for diagnosis and therapy of movement disorders Nat. Nanotechnol. 9 397-404
[5]  
Roglic G(2016)An intra-oral drug delivery system design for painless, long-term and continuous drug release Sens. Actuator B Chem. 227 573-582
[6]  
Green A(2016)Flexible and stretchable physical sensor integrated platforms for wearable human-activity monitoring and personal healthcare Adv. Mater. 28 4338-4372
[7]  
Sicree R(2016)Flexible piezoresistive sensor patch enabling ultralow power cuffless blood pressure measurement Adv. Funct. Mater. 26 1178-1187
[8]  
King H(2013)In vivo biosensing via tissue-localizable near-infrared-fluorescent single-walled carbon nanotubes Nat. Nanotechnol. 8 873-880
[9]  
Gani A(2015)Neurogrid: recording action potentials from the surface of the brain Nat. Neurosci. 18 310-315
[10]  
Gribok AV(2017)Miniaturized battery-free wireless systems for wearable pulse oximetry Adv. Funct. Mater. 27 1604373-102