Jetting Dispenser Height Effect on the Accuracy of Test Strip for Blood Glucose

被引:0
作者
Kun-Yong Kim
Yi-Cheng Lee
Ho Chang
Rahn-Fang Lee
Hong-Wei Wu
机构
[1] National Taipei University of Technology,Graduate Institute of Manufacturing Technology
来源
Journal of Medical and Biological Engineering | 2019年 / 39卷
关键词
Nozzle height; Jetting dispenser; Biosensor; Blood glucose test strip; Standard deviation; Coefficient of variation;
D O I
暂无
中图分类号
学科分类号
摘要
This study explores the application of Jetting Dispensers to dispense droplets of glucose oxidase enzyme solution onto blood test strips of immersion gold-plated printed circuit boards. Each droplet must contain the same weight of glucose oxidase enzyme solution, and the jetting dispensing must be within the reaction area of test strip while wrapping around the golden electrodes. Experimental results show that the height at which the droplets of glucose oxidase enzyme solution are jet dispensed onto the test strip reaction area significantly affects the glucose test strip. A dispensing machine with a jet dispensing height of 1.3 mm produces droplets in the test strip area that are all the shape of arc beads. Therefore, test strips have lower standard deviation (STD) and coefficient of variation (CV) when dispensed at 1.3 mm than at heights of 1.1 and 1.5 mm. This study confirms that the optimum jet dispensing height parameter with respect to enzyme compound is 1.3 mm.
引用
收藏
页码:109 / 116
页数:7
相关论文
共 19 条
  • [1] Ahamed MJ(2010)A piezoactuated droplet-dispensing microfluidic chip Journal of Microelectromechanical Systems 19 110-119
  • [2] Gubarenko SI(2012)A development of dispenser for high-viscosity liquid and pick and place of micro objects using capillary force Key Engineering Materials 516 48-53
  • [3] Ben-Mrad R(2013)Design and experiment of a jetting dispenser driven by piezostack actuator IEEE Transactions on Components, Packaging and Manufacturing Technology 3 147-156
  • [4] Sullivan P(2013)Model fluids representing aqueous in-vitro diagnostic reagents for the development of dispensing systems Drug Discovery Today 18 1035-1042
  • [5] Kumagai K(2009)The chemistry of commercial continuous glucose monitors Diabetes Technology and Therapeutics 11 17-24
  • [6] Fuchiwaki O(undefined)undefined undefined undefined undefined-undefined
  • [7] Wang L(undefined)undefined undefined undefined undefined-undefined
  • [8] Du J(undefined)undefined undefined undefined undefined-undefined
  • [9] Luo Z(undefined)undefined undefined undefined undefined-undefined
  • [10] Du X(undefined)undefined undefined undefined undefined-undefined