The Potted-Plant Microcosm Substantially Reduces Indoor Air VOC Pollution: I. Office Field-Study

被引:0
作者
Ronald A. Wood
Margaret D. Burchett
Ralph Alquezar
Ralph L. Orwell
Jane Tarran
Fraser Torpy
机构
[1] University of Technology,Plants and Environmental Quality Group, Faculty of Science
来源
Water, Air, and Soil Pollution | 2006年 / 175卷
关键词
indoor air pollution; VOC; TVOC; “sick-building syndrome”; “building-related illness” environmental biotechnology; bioremediation; phytoremediation; potted-plant;
D O I
暂无
中图分类号
学科分类号
摘要
Volatile organic compounds (VOCs) are major contaminants of indoor air, with concentrations often several times higher than outdoors. They are recognized as causative agents of “building-related illness” or “sick-building syndrome”. Our previous laboratory test-chamber studies have shown that the potted-plant/root-zone microorganism microcosm can eliminate high concentrations of air-borne VOCs within 24 hours, once the removal response has been induced by an initial dose. However, the effectiveness of the potted-plant microcosm in ‘real-world’ indoor spaces has never previously been tested experimentally. This paper reports the results of a field-study on the effects of potted-plant presence on total VOC (TVOC) levels, measured in 60 offices (12 per treatment), over two 5–9 week periods, using three planting regimes, with two ‘international indoor-plant’ species. Fourteen VOCs were identified in the office air. When TVOC loads in reference offices rose above 100 ppb, large reductions, of from 50 to 75% (to <100 ppb), were found in planted offices, under all planting regimes The results indicate that air-borne TVOC levels above a threshold of about 100 ppb stimulate the graded induction of an efficient metabolic VOC-removal mechanism in the microcosm. Follow-up laboratory dose-response experiments, reported in the following paper, confirm the graded induction response, over a wide range of VOC concentrations. The findings together demonstrate that potted-plants can provide an efficient, self-regulating, low-cost, sustainable, bioremediation system for indoor air pollution, which can effectively complement engineering measures to reduce indoor air pollution, and hence improve human wellbeing and productivity.
引用
收藏
页码:163 / 180
页数:17
相关论文
共 72 条
  • [1] Brown S. K.(1994)Concentrations of volatile organic compounds in indoor air — a review Indoor Air 4 123-134
  • [2] Sim M. R.(1998)Human health effects of environmental pollutants: new insights Environ. Monit. Assessmt 53 245-258
  • [3] Abramson M. J.(1999)Air conditioning and noise control using vegetation, In Proceedings of Indoor Air '99, Edinburgh International Conference on Indoor Air Quality and Climate 3 234-239
  • [4] Gray C. N.(2003)Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information Indoor Air 13 53-64
  • [5] Carpenter D. O.(2000)The biofiltration of indoor air: implications for air quality Indoor Air 10 39-46
  • [6] Costa P. R.(1994)Detoxification of formaldehyde by the spider plant (Chlorophytum comosum L.) and by soybean (Glycine max L.) cell-suspension cultures Plant Physiology 104 1301-1309
  • [7] James R. W.(2002)Linkages between aboveground plant communities and soil-borne microbial diversity Abs. Gen. Meet. Amer. Soc. Microbiol 102 309-8
  • [8] Daisey J. M.(2003)Field evidence of rhizosphere enrichment of PCB-degrading bacteria Abs. Gen. Meet. Amer. Soc. Microbiol. 103 117-458
  • [9] Angell W. J.(1996)Particulate matter accumulation on horizontal surfaces in interiors: influence of foliage plants. Atmospheric Environment 30 2565-1440
  • [10] Apte M. G.(2003)Hydrocarbon degradation and enzyme activities of cold-adapted bacteria and yeasts Extremophiles 7 415-53