The possibilities offered by use of solid insulation in complete switching gears and cross-linked polyethylene insulation under direct and alternating current

被引:1
|
作者
Shul’ga R.N. [1 ]
Shul’ga A.R. [2 ]
Kovalev D.I. [3 ]
Mirzabekyan G.Z. [3 ]
Varivodov V.N. [3 ]
机构
[1] Federal State Unitary Enterprise Lenin All-Russia Electrotechnical Institute, Moscow
[2] OOO Eurocom, Moscow
[3] Federal State Budgetary Educational Institution of Higher Education, National Research University, Moscow Power Engineering Institute (MPEI), Moscow
关键词
alternating current; cables; cross-linked polyethylene; direct current; solid insulation; space charge; switching gear;
D O I
10.3103/S1068371216080083
中图分类号
学科分类号
摘要
The prospects for use of energy cables with cross-linked polyethylene insulation (CLPE) and switching gears with solid insulation under direct and alternating current are considered. The main developments in the work of enterprises manufacturing cable products are listed, and their main characteristics are given. The advantages of cables lines with cross-linked polyethylene insulation over cable lines with paper–oil insulation are described: increased capacity, high permissible insulation temperature, smaller cable bend radius, smaller weight–size parameters, increased service life, the possibility of being laid at low temperatures, and high environmental characteristics. The global experience and main problems of application of cross-linked polyethylene insulation cables under direct high-voltage current are analyzed. The variants of performance of the insulation and structure of 6–35 kV switching gears of different producers are studied. Some functions of switching gear, typical structures, and equipment structure are listed, and the main test modes for insulation of separated section and units of the switching gears are described. Different types of solid insulation of complete switching gears (CSGs) of medium voltage are compared: with and without a grounded shield on the surface. Reduced weight–size parameters and increased electrical safety are identified as advantages of the structure with a shield. Data on perspective Russian development in the area of complete switching gears and solid insulation are presented, and the conclusions regarding their main advantages are drawn. The basic functional of the system of control and monitoring by new-generation switching gear of the is offered. © 2016, Allerton Press, Inc.
引用
收藏
页码:462 / 466
页数:4
相关论文
共 50 条
  • [1] A Review on the Aging Performance of Direct Current Cross-linked Polyethylene Insulation Materials
    Zhang, Chengcheng
    Li, Chunyang
    Zhao, Hong
    Han, Baozhong
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 700 - 703
  • [2] MORPHOLOGY OF CROSS-LINKED POLYETHYLENE INSULATION
    MUCCIGROSSO, J
    PHILLIPS, PJ
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1978, 13 (03): : 172 - 178
  • [3] CROSS-LINKED POLYETHYLENE INSULATION - CHARACTERIZATION OF VOLATILES
    MEHTA, AA
    HUANG, SJ
    JOHNSON, JF
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 32 - PMSE
  • [4] IONIC IMPURITIES IN CROSS-LINKED POLYETHYLENE CABLE INSULATION
    GARTON, A
    GROEGER, JH
    HENRY, JL
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1990, 25 (02): : 427 - 434
  • [5] ETCHING AND THE MORPHOLOGY OF CROSS-LINKED POLYETHYLENE CABLE INSULATION
    BAMJI, S
    BULINSKI, A
    DENSLEY, J
    GARTON, A
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1983, 18 (01): : 32 - 41
  • [6] Prediction of residual stresses in cross-linked polyethylene cable insulation
    Olasz, L
    Gudmundson, P
    POLYMER ENGINEERING AND SCIENCE, 2005, 45 (08): : 1132 - 1139
  • [7] CHARACTERIZATION OF CLOUDS IN CROSS-LINKED POLYETHYLENE (XLPE) CABLE INSULATION
    NIEGISCH, WD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 191 : 131 - PMSE
  • [9] Analysis of the insulation deterioration of high voltage cross-linked polyethylene power cables (XLPE) under switching impulses stress
    Pamuk, N.
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2014, 16 (11-12): : 1392 - 1399
  • [10] The electrical properties and processing characteristic of the cross-linked polyethylene based insulation for high-voltage direct current cables
    Li, Weikang
    Yan, Hongda
    Li, Wenpeng
    Zhang, Chong
    Yu, Fan
    Shi, Xiaoning
    Zhao, Weijia
    2019 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE 2019), 2019, : 341 - 344