The effect of the boron-ions implantation on the performance of RADFETs

被引:0
作者
HongRui Liu
ShuaiMin Wang
JinWen Zhang
机构
[1] Peking University,Institute of Microelectronics
[2] Peking University,National Key Laboratory of Science and Technology on Micro/Nano Fabrication
来源
Science China Technological Sciences | 2016年 / 59卷
关键词
dosimeters; PMOS RADFETs; implant dose; post-annealing temperature; real time auto-measurement system; radiation effects;
D O I
暂无
中图分类号
学科分类号
摘要
In this work, we studied on the boron-ions implantation, including the implant dose and post-annealing temperature on the performance of PMOS radiation field-effect transistors (RADFETs) in experimental. The possible traps and defects induced by ions implantation in the gate-oxide and their further impacting on the sensitivity and dose range of RADFETs were analyzed qualitatively. Our devices had the dry/wet/dry sandwich gate-oxide of 420 nm thick. Different ion-implanting doses and post-annealing temperatures were carried out during the RADFETs fabrication. We built a real time auto-measurement system to realize the auto-state-switch between irradiation and read-out modes, and in-situ measurement of output voltage for ten devices in turn at once of radiation experiment. The threshold voltage, dose range and sensitivity of RADFETs were extracted and analyzed in detail. The results showed that the highest sensitivity of 229 mV/Gy achieved when the implant dose was 2.2×1011 cm−2 and the post-annealing temperature was 1000°C, and the dose range of 34 Gy as well.
引用
收藏
页码:1785 / 1790
页数:5
相关论文
共 67 条
[11]  
Patle A(2013)Development of the radiation sensitivity of PMOS dosimeters Nucl Technol Radiat Prot 28 415-59
[12]  
Patil R R(1991)Investigation of on-chip high temperature annealing of PMOS dosimeters Radiation and its Effects on Devices and Systems 91 57-396
[13]  
Kulkarni M S(2015)The gamma-ray irradiation sensitivity and dosimetric information instability of RADFET dosimeter Sci China Tech Sci 58 390-990
[14]  
Hajdas W(1996)MOS radiation dosimeter: Sensitivity and stability IEEE T Nucl Sci 43 985-295
[15]  
Bialkowski J(2006)Impact of TID on response to pulsed X-ray irradiation in the bipolar operational amplifier Sens Actuat A-Phys 125 288-1276
[16]  
Wyser U(2003)Stacked RADFETs for increased radiation sensitivity Proc IEEE Sensors 2 1271-1612
[17]  
FröHlich L(1978)Evaluation of a low-cost commercial MOSFET as radiation dosimeter IEEE T Nucl Sci 25 1607-2009
[18]  
Casarin K(1984)A sensitive floating gate MOSFET gamma ray dosimeter J Chem Phys 81 1994-499
[19]  
Quai E(2003)The development of an MOS dosimetry unit for use in space IEEE T Nucl Sci 50 483-1338
[20]  
Holmes-Siedle A(2015)Theory of geminate recombination on a lattice Sci China Tech Sci 58 1333-1403