The effect of the boron-ions implantation on the performance of RADFETs

被引:0
作者
HongRui Liu
ShuaiMin Wang
JinWen Zhang
机构
[1] Peking University,Institute of Microelectronics
[2] Peking University,National Key Laboratory of Science and Technology on Micro/Nano Fabrication
来源
Science China Technological Sciences | 2016年 / 59卷
关键词
dosimeters; PMOS RADFETs; implant dose; post-annealing temperature; real time auto-measurement system; radiation effects;
D O I
暂无
中图分类号
学科分类号
摘要
In this work, we studied on the boron-ions implantation, including the implant dose and post-annealing temperature on the performance of PMOS radiation field-effect transistors (RADFETs) in experimental. The possible traps and defects induced by ions implantation in the gate-oxide and their further impacting on the sensitivity and dose range of RADFETs were analyzed qualitatively. Our devices had the dry/wet/dry sandwich gate-oxide of 420 nm thick. Different ion-implanting doses and post-annealing temperatures were carried out during the RADFETs fabrication. We built a real time auto-measurement system to realize the auto-state-switch between irradiation and read-out modes, and in-situ measurement of output voltage for ten devices in turn at once of radiation experiment. The threshold voltage, dose range and sensitivity of RADFETs were extracted and analyzed in detail. The results showed that the highest sensitivity of 229 mV/Gy achieved when the implant dose was 2.2×1011 cm−2 and the post-annealing temperature was 1000°C, and the dose range of 34 Gy as well.
引用
收藏
页码:1785 / 1790
页数:5
相关论文
共 67 条
[1]  
Holmes-Siedle A(1974)The space-charge dosimeter: General principles of a new method of radiation detection Nucl Instrum Meth 121 169-179
[2]  
Hughes R C(1988)Miniature radiation dosimeter for Int J Radiat Oncol 14 963-967
[3]  
Huffman D(2015) radiation measurements Aust Phys Eng Sci Med 38 465-472
[4]  
Snelling J V(2015)Monte Carlo and experimental internal radionuclide dosimetry in RANDO head phantom EPJ Web of Conferences 100 04001-189
[5]  
Ghahraman Asl R(2015)Investigation of temperature dependence of semiconductor detectors used in medicine for radiation measurements Opt Mater 48 185-113
[6]  
Nasseri S(1999)Highly sensitive europium doped SrSO Radiation and Its Effects on Components and Systems 99 110-79
[7]  
Parach A A(2013) OSL nanophosphor for radiation dosimetry applications Nucl Instrum Meth A 703 70-69
[8]  
Altunkok S O(1991)Sensitivity of the SREM RADFET dosimeters for STRV-1c to various proton and gamma radiation environments Radiation and its Effects on Devices and Systems 91 65-346
[9]  
Tuncel N(1992)Online monitoring of absorbed dose in undulator magnets with RADFET dosimeters at FERMI@Elettra IEEE T Nucl Sci 39 342-1001
[10]  
Ucar N(1996)MOS dosimeters-improvement of responsivity IEEE T Nucl Sci 43 997-421