摘要
Continuous Positive Airway Pressure (CPAP) ventilation remains a mainstay treatment for obstructive sleep apnea syndrome (OSAS). Good pressure stability and pressure reduction during exhalation are of major importance to ensure clinical efficacy and comfort of CPAP therapy. In this study an experimental CPAP ventilator was constructed using an application-specific CPAP blower/motor assembly and a microprocessor. To minimize pressure variations caused by spontaneous breathing as well as the uncomfortable feeling of exhaling against positive pressure, we developed a composite control approach including the feed forward compensator and feedback proportional-integral-derivative (PID) compensator to regulate the pressure delivered to OSAS patients. The Ziegler and Nichols method was used to tune PID controller parameters. And then we used a gas flow analyzer (VT PLUS HF) to test pressure curves, flow curves and pressure-volume loops for the proposed CPAP ventilator. The results showed that it met technical criteria for sleep apnea breathing therapy equipment. Finally, the study made a quantitative comparison of pressure stability between the experimental CPAP ventilator and commercially available CPAP devices.
引用
收藏
相关论文
共 50 条
  • [1] Control system design for a continuous positive airway pressure ventilator
    Chen, Zheng-Long
    Hu, Zhao-Yan
    Dai, Hou-De
    BIOMEDICAL ENGINEERING ONLINE, 2012, 11
  • [2] Control Module Design for a Continuous Positive Airway Pressure Ventilator
    Dai, Min
    Zhang, Zhisheng
    Liu, Zhigang
    Yin, Dongfu
    MECHATRONICS AND INDUSTRIAL INFORMATICS, PTS 1-4, 2013, 321-324 : 1657 - +
  • [3] Control system for continuous positive airway pressure
    1600, Sociedade Brasileira de Engenharia Biomedica, Caixa Postal 68510, Rio de Janeiro, RJ, 21941-972, Brazil (30):
  • [4] USING TRACHEAL PRESSURE TO TRIGGER THE VENTILATOR AND CONTROL AIRWAY PRESSURE DURING CONTINUOUS POSITIVE AIRWAY PRESSURE DECREASES WORK OF BREATHING
    MESSINGER, G
    BANNER, MJ
    BLANCH, PB
    LAYON, AJ
    CHEST, 1995, 108 (02) : 509 - 514
  • [5] A comparison of underwater bubble continuous positive airway pressure with ventilator-derived continuous positive airway pressure in premature neonates ready for extubation
    Lee, KS
    Dunn, MS
    Fenwick, M
    Shennan, AT
    BIOLOGY OF THE NEONATE, 1998, 73 (02): : 69 - 75
  • [6] CONTINUOUS POSITIVE AIRWAY PRESSURE - NEW SYSTEM
    PFITZNER, J
    BRANTHWA.MA
    ENGLISH, ICW
    SHINEBOU.EA
    ANAESTHESIA, 1974, 29 (03) : 326 - 334
  • [7] Continuous Positive Airway Pressure Strategies with Bubble Nasal Continuous Positive Airway Pressure Not All Bubbling Is the Same: The Seattle Positive Airway Pressure System
    Welty, Stephen E.
    CLINICS IN PERINATOLOGY, 2016, 43 (04) : 661 - +
  • [8] Evaluation of a continuous positive airway pressure system without a ventilator to treat acute respiratory failure in children
    Sanabria Carretero, P.
    Palomero Rodriguez, M. A.
    Laporta Baez, Y.
    Martinez de Bujo, B. Suso
    Suarez Gonzalo, L.
    Muriel Villoria, C.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2008, 55 (10): : 621 - 625
  • [9] ALARM SYSTEM FOR PRESSURE FAILURES IN CONTINUOUS POSITIVE AIRWAY PRESSURE
    HOGAN, WE
    INDYK, L
    JOURNAL OF PEDIATRICS, 1973, 82 (03): : 485 - 486
  • [10] SAFETY OF A NEW SYSTEM FOR CONTINUOUS POSITIVE AIRWAY PRESSURE
    JENKINS, JG
    VANBESOUW, JP
    ANAESTHESIA, 1986, 41 (11) : 1155 - 1156