Development of a biological signal-based evaluator for robot-assisted upper-limb rehabilitation: a pilot study

被引:0
作者
Bo Sheng
Lihua Tang
Oscar Moroni Moosman
Chao Deng
Shane Xie
Yanxin Zhang
机构
[1] The University of Auckland,Department of Mechanical Engineering
[2] The University of Auckland,Department of Exercise Sciences
[3] Huazhong University of Science & Technology,School of Mechanical Science & Engineering
[4] The University of Leeds,School of Electronic and Electrical Engineering
来源
Australasian Physical & Engineering Sciences in Medicine | 2019年 / 42卷
关键词
Upper-limb function evaluator; Interaction force; Participation level; Standardized performance testing; sEMG signals;
D O I
暂无
中图分类号
学科分类号
摘要
Bio-signal based assessment for upper-limb functions is an attractive technology for rehabilitation. In this work, an upper-limb function evaluator is developed based on biological signals, which could be used for selecting different robotic training protocols. Interaction force (IF) and participation level (PL, processed surface electromyography (sEMG) signals) are used as the key bio-signal inputs for the evaluator. Accordingly, a robot-based standardized performance testing (SPT) is developed to measure these key bio-signal data. Moreover, fuzzy logic is used to regulate biological signals, and a rules-based selector is then developed to select different training protocols. To the authors’ knowledge, studies focused on biological signal-based evaluator for selecting robotic training protocols, especially for robot-based bilateral rehabilitation, has not yet been reported in literature. The implementation of SPT and fuzzy logic to measure and process key bio-signal data with a rehabilitation robot system is the first of its kind. Five healthy participants were then recruited to test the performance of the SPT, fuzzy logic and evaluator in three different conditions (tasks). The results show: (1) the developed SPT has an ability to measure precise bio-signal data from participants; (2) the utilized fuzzy logic has an ability to process the measured data with the accuracy of 86.7% and 100% for the IF and PL respectively; and (3) the proposed evaluator has an ability to distinguish the intensity of biological signals and thus to select different robotic training protocols. The results from the proposed evaluator, and biological signals measured from healthy people could also be used to standardize the criteria to assess the results of stroke patients later.
引用
收藏
页码:789 / 801
页数:12
相关论文
共 156 条
  • [1] Sheng B(2016)Bilateral robots for upper-limb stroke rehabilitation: state of the art and future prospects Med Eng Phys 38 587-606
  • [2] Zhang Y(2014)A survey on robotic devices for upper limb rehabilitation J Neuroeng Rehabil 11 3-31
  • [3] Meng W(1975)The post-stroke hemiplegic patient. 1. a method for evaluation of physical performance Scand J Rehabil Med 7 13-207
  • [4] Deng C(1987)Interrater reliability of a modified Ashworth scale of muscle spasticity Phys Ther 67 206-69
  • [5] Xie S(2010)Kinematic robot-based evaluation scales and clinical counterparts to measure upper limb motor performance in patients with chronic stroke Neurorehabil Neural Repair 24 62-889
  • [6] Maciejasz P(2009)Gait speed at usual pace as a predictor of adverse outcomes in community-dwelling older people an International Academy on Nutrition and Aging (IANA) Task Force J Nutr Health Aging 13 881-20114
  • [7] Eschweiler J(2015)A framework to automate assessment of upper-limb motor function impairment: a feasibility study Sensors 15 20097-S269
  • [8] Gerlach-Hahn K(2012)Robotic assessment of upper limb motor function after stroke Am J Phys Med Rehabil 91 S255-727
  • [9] Jansen-Troy A(2014)Quantitative assessment based on kinematic measures of functional impairments during upper extremity movements: a review Clin Biomech 29 719-87
  • [10] Leonhardt S(2014)Assessment of movement quality in robot-assisted upper limb rehabilitation after stroke: a review J Neuroeng Rehabil 11 137-370