摘要
Tuberculosis (TB), an infectious disease caused by Mycobacterium tuberculosis, infects approximately one third of the current world population. Isoniazid is one of the most frequently used first-line anti-TB drugs. In this study, we developed a sensitive cation-selective exhaustive injection–sweeping–micellar electrokinetic chromatography method (CSEI-Sweep-MEKC) for analyzing isoniazid in human plasma. Parameters including acetonitrile (ACN) percentage in the separation buffer; the injection time, and concentration of the high-conductivity buffer; sodium dodecyl sulfate (SDS) concentration; phosphate concentration in the sample matrix; and the sample injection time were all optimized to obtain the best analytical performance. The optimal background electrolyte comprised 50 mM phosphate buffer, 100 mM SDS, and 15% ACN. Non-micelle background electrolyte, containing 75 mM phosphate buffer and 15% ACN, was first injected into the capillary, followed by a short plug of 200 mM phosphate (high-conductivity buffer). Run-to-run repeatability (n = 3) and intermediate precision (n = 3) of peak area ratios were found to be lower than 8.7% and 11.4% RSD, respectively. The accuracy of the method was within 98.1–106.9%. The limit of detection of isoniazod in human plasma was 9 ng mL−1. Compared with conventional MEKC, the enhancement factor of the CSEI-Sweep-MEKC method was 85 in plasma samples. The developed method was successfully used to determine isoniazid concentration in patient plasma. The results demonstrated that CSEI-Sweep-MEKC has the potential to analyze isoniazid in human plasma for therapeutic drug monitoring and clinical research.
引用
收藏
页码:2205 / 2214
页数:9
相关论文
共 159 条
[1]  
Berning SE(1992)Malabsorption of antituberculosis medications by a patient with AIDS N Engl J Med 327 1817-1818
[2]  
Huitt GA(2003)Managing antituberculosis drug therapy by therapeutic drug monitoring of rifampicin and isoniazid Intern Med J 33 229-234
[3]  
Iseman MD(1995)Drug malabsorption and resistant tuberculosis in HIV-infected patients N Engl J Med 332 336-337
[4]  
Peloquin CA(1972)Determination of isoniazid and its metabolites acetylisoniazid, monoacetylhydrazine, diazetylhydrazine, isonicotinic acid and isonicotinylglycine in serum and urine Biochem J 126 449-458
[5]  
Ray J(1971)More sensitive spectrophotometric method for determination of isoniazid in serum or plasma Clin Chem 17 492-494
[6]  
Gardiner I(1978)Spectrophotometric determination of isoniazid in presence of its hydrazones J Pharm Sci 67 661-663
[7]  
Marriott D(1972)Rapid fluorometric or spectrophotometric determination of isoniazid Biochem Med 6 65-71
[8]  
Patel KB(2010)Simultaneous determination of isoniazid, pyrazinamide, rifampicin and acetylisoniazid in human plasma by high-performance liquid chromatography Anal Sci 26 1133-1138
[9]  
Belmonte R(2007)Simultaneous HPLC determination of isoniazid and acetylisoniazid in plasma Acta Chromatogr 19 110-118
[10]  
Crowe HM(2010)Development and validation of a novel gradient LC method for simultaneous determination of isoniazid and acetylisoniazid in human plasma Chromatographia 71 419-422